[Go back to index]

Asobo_EX1\(Base\)Component\Visibility.xml

Source XML

<ModelBehaviors> <!– ParametersFn Definitions –> <ParametersFn Name=“ASOBO_Visibility_Base_Default_Parameters”> <ReturnParameters> <VISIBILITY_DO_ONCE>False</VISIBILITY_DO_ONCE> </ReturnParameters> </ParametersFn> <ParametersFn Name=“ASOBO_Visibility_Base_Parameters”> <ReturnParameters> <ONCE>#VISIBILITY_DO_ONCE#</ONCE> </ReturnParameters> </ParametersFn> <ParametersFn Name=“ASOBO_Visibility_Sim_Default_Parameters”> <ReturnParameters> <VISIBILITY_SIMVAR/> <VISIBILITY_SIMVAR_UNITS/> <VISIBILITY_SIMVAR_SCALE>1</VISIBILITY_SIMVAR_SCALE> <VISIBILITY_SIMVAR_BIAS>0</VISIBILITY_SIMVAR_BIAS> </ReturnParameters> </ParametersFn> <ParametersFn Name=“ASOBO_Visibility_Sim_Base_Parameters”> <Parameters Type=“Default”> <UseParametersFn Name=“ASOBO_Visibility_Base_Default_Parameters”/> <UseParametersFn Name=“ASOBO_Visibility_Sim_Default_Parameters”/> </Parameters> <ReturnParameters> <UseParametersFn Name=“ASOBO_PFN_Call_Overridable_ParametersFn_Helper”> <PFN_PARAM_DEFAULT>ASOBO_Visibility_Base_Parameters</PFN_PARAM_DEFAULT> <PFN_PARAM_NAME>VISIBILITY_BASE_PARAMETERS_FN</PFN_PARAM_NAME> </UseParametersFn> <SIMVAR>#VISIBILITY_SIMVAR#</SIMVAR> <UNITS>#VISIBILITY_SIMVAR_UNITS#</UNITS> <SCALE>#VISIBILITY_SIMVAR_SCALE#</SCALE> <BIAS>#VISIBILITY_SIMVAR_BIAS#</BIAS> </ReturnParameters> </ParametersFn> <ParametersFn Name=“ASOBO_Visibility_Code_Base_Parameters”> <Parameters Type=“Default”> <UseParametersFn Name=“ASOBO_Visibility_Base_Default_Parameters”/> </Parameters> <Parameters Type=“Override”> <Condition CheckSavedParameters=“Visibility_Code_Transform_Stack”> <UseParametersFn Name=“ASOBO_Visibility_Code_Transform_Value”> <PLOAD_VISIBILITY_CODE_TRANSFORMS>Visibility_Code_Transform_Stack</PLOAD_VISIBILITY_CODE_TRANSFORMS> </UseParametersFn> </Condition> </Parameters> <ReturnParameters> <UseParametersFn Name=“ASOBO_PFN_Call_Overridable_ParametersFn_Helper”> <PFN_PARAM_DEFAULT>ASOBO_Visibility_Base_Parameters</PFN_PARAM_DEFAULT> <PFN_PARAM_NAME>VISIBILITY_BASE_PARAMETERS_FN</PFN_PARAM_NAME> </UseParametersFn> <CODE>#VISIBILITY_CODE#</CODE> </ReturnParameters> </ParametersFn> <ParametersFn Name=“ASOBO_Visibility_Code_Transform_Value”> <Parameters Type=“Override”> <UseParametersFn Name=“ASOBO_Load_Then_Remove_Parameters_Helper”> <SAVED_PARAMETERS>PLOAD_VISIBILITY_CODE_TRANSFORMS</SAVED_PARAMETERS> </UseParametersFn> </Parameters> <ReturnParameters> <Loop> <Setup> <Param>CUR_ID</Param> <From>0</From> <Inc>1</Inc> <While> <Arg Valid=“VISIBILITY_CODE_TRANSFORM_PFN_#CUR_ID#”/> </While> </Setup> <Do> <Parameters Type=“Override”> <VISIBILITY_CODE_TRANSFORM_PFN Process=“Param”>VISIBILITY_CODE_TRANSFORM_PFN_#CUR_ID#</VISIBILITY_CODE_TRANSFORM_PFN> </Parameters> <Parameters Type=“Override” Lifetime=“Loop”> <UseParametersFn Name="#VISIBILITY_CODE_TRANSFORM_PFN#"/> </Parameters> </Do> <Then> <Condition Check=“VISIBILITY_CODE_TRANSFORM_PFN_RETURN”> <True> <UseParametersFn Name="#VISIBILITY_CODE_TRANSFORM_PFN_RETURN#"/> </True> <False> <VISIBILITY_CODE>#VISIBILITY_CODE#</VISIBILITY_CODE> </False> </Condition> </Then> </Loop> </ReturnParameters> </ParametersFn> <!– Template Definitions –> <Template Name=“ASOBO_Visibility_Template”> <Switch> <Case NotEmpty=“VISIBILITY_CODE”> <UseTemplate Name=“ASOBO_Visibility_Code_Base_Template”/> </Case> <Case NotEmpty=“VISIBILITY_SIMVAR”> <UseTemplate Name=“ASOBO_Visibility_Sim_Base_Template”/> </Case> </Switch> </Template> <Template Name=“ASOBO_Visibility_Sim_Base_Template”> <Parameters Type=“Override”> <UseParametersFn Name=“ASOBO_PFN_Call_Overridable_ParametersFn_Helper”> <PFN_PARAM_DEFAULT>ASOBO_Visibility_Sim_Base_Parameters</PFN_PARAM_DEFAULT> <PFN_PARAM_NAME>VISIBILITY_SIM_BASE_PARAMETERS_FN</PFN_PARAM_NAME> </UseParametersFn> </Parameters> <Visibility Once="#ONCE#"> <Parameter> <Sim> <Variable>#SIMVAR#</Variable> <Units>#UNITS#</Units> <Scale>#SCALE#</Scale> <Bias>#BIAS#</Bias> </Sim> </Parameter> </Visibility> </Template> <Template Name=“ASOBO_Visibility_Code_Base_Template”> <Parameters Type=“Override”> <UseParametersFn Name=“ASOBO_PFN_Call_Overridable_ParametersFn_Helper”> <PFN_PARAM_DEFAULT>ASOBO_Visibility_Code_Base_Parameters</PFN_PARAM_DEFAULT> <PFN_PARAM_NAME>VISIBILITY_CODE_BASE_PARAMETERS_FN</PFN_PARAM_NAME> </UseParametersFn> </Parameters> <Visibility Once="#ONCE#"> <Parameter> <Code>#CODE#</Code> </Parameter> </Visibility> </Template> </ModelBehaviors>

 

 

Templates

Template list

  1. ASOBO_Visibility_Template
  2. ASOBO_Visibility_Sim_Base_Template
  3. ASOBO_Visibility_Code_Base_Template
  • ASOBO_Visibility_Template

    Definition from XML

    <Template Name=“ASOBO_Visibility_Template”> <Switch> <Case NotEmpty=“VISIBILITY_CODE”> <UseTemplate Name=“ASOBO_Visibility_Code_Base_Template”/> </Case> <Case NotEmpty=“VISIBILITY_SIMVAR”> <UseTemplate Name=“ASOBO_Visibility_Sim_Base_Template”/> </Case> </Switch> </Template>

    Condition: Switch

    [Go back to top] [Go back to index]

  • ASOBO_Visibility_Sim_Base_Template

    Definition from XML

    <Template Name=“ASOBO_Visibility_Sim_Base_Template”> <Parameters Type=“Override”> <UseParametersFn Name=“ASOBO_PFN_Call_Overridable_ParametersFn_Helper”> <PFN_PARAM_DEFAULT>ASOBO_Visibility_Sim_Base_Parameters</PFN_PARAM_DEFAULT> <PFN_PARAM_NAME>VISIBILITY_SIM_BASE_PARAMETERS_FN</PFN_PARAM_NAME> </UseParametersFn> </Parameters> <Visibility Once="#ONCE#"> <Parameter> <Sim> <Variable>#SIMVAR#</Variable> <Units>#UNITS#</Units> <Scale>#SCALE#</Scale> <Bias>#BIAS#</Bias> </Sim> </Parameter> </Visibility> </Template>

    Parameters initialization:

    Parameters read:

    • ONCE
    • SIMVAR
    • UNITS
    • SCALE
    • BIAS

    [Go back to top] [Go back to index]

  • ASOBO_Visibility_Code_Base_Template

    Definition from XML

    <Template Name=“ASOBO_Visibility_Code_Base_Template”> <Parameters Type=“Override”> <UseParametersFn Name=“ASOBO_PFN_Call_Overridable_ParametersFn_Helper”> <PFN_PARAM_DEFAULT>ASOBO_Visibility_Code_Base_Parameters</PFN_PARAM_DEFAULT> <PFN_PARAM_NAME>VISIBILITY_CODE_BASE_PARAMETERS_FN</PFN_PARAM_NAME> </UseParametersFn> </Parameters> <Visibility Once="#ONCE#"> <Parameter> <Code>#CODE#</Code> </Parameter> </Visibility> </Template>

    Parameters initialization:

    Parameters read:

    • ONCE
    • CODE

    [Go back to top] [Go back to index]

ParametersFn

  • ASOBO_Visibility_Base_Default_Parameters

    Definition from XML

    <ParametersFn Name=“ASOBO_Visibility_Base_Default_Parameters”> <ReturnParameters> <VISIBILITY_DO_ONCE>False</VISIBILITY_DO_ONCE> </ReturnParameters> </ParametersFn>

    Return parameters:

    Parameters set:

    • VISIBILITY_DO_ONCE
  • ASOBO_Visibility_Base_Parameters

    Definition from XML

    <ParametersFn Name=“ASOBO_Visibility_Base_Parameters”> <ReturnParameters> <ONCE>#VISIBILITY_DO_ONCE#</ONCE> </ReturnParameters> </ParametersFn>

    Return parameters:

    Parameters set:

    • ONCE (using VISIBILITY_DO_ONCE)
  • ASOBO_Visibility_Sim_Default_Parameters

    Definition from XML

    <ParametersFn Name=“ASOBO_Visibility_Sim_Default_Parameters”> <ReturnParameters> <VISIBILITY_SIMVAR/> <VISIBILITY_SIMVAR_UNITS/> <VISIBILITY_SIMVAR_SCALE>1</VISIBILITY_SIMVAR_SCALE> <VISIBILITY_SIMVAR_BIAS>0</VISIBILITY_SIMVAR_BIAS> </ReturnParameters> </ParametersFn>

    Return parameters:

    Parameters set:

    • VISIBILITY_SIMVAR
    • VISIBILITY_SIMVAR_UNITS
    • VISIBILITY_SIMVAR_SCALE
    • VISIBILITY_SIMVAR_BIAS
  • ASOBO_Visibility_Sim_Base_Parameters

    Definition from XML

    <ParametersFn Name=“ASOBO_Visibility_Sim_Base_Parameters”> <Parameters Type=“Default”> <UseParametersFn Name=“ASOBO_Visibility_Base_Default_Parameters”/> <UseParametersFn Name=“ASOBO_Visibility_Sim_Default_Parameters”/> </Parameters> <ReturnParameters> <UseParametersFn Name=“ASOBO_PFN_Call_Overridable_ParametersFn_Helper”> <PFN_PARAM_DEFAULT>ASOBO_Visibility_Base_Parameters</PFN_PARAM_DEFAULT> <PFN_PARAM_NAME>VISIBILITY_BASE_PARAMETERS_FN</PFN_PARAM_NAME> </UseParametersFn> <SIMVAR>#VISIBILITY_SIMVAR#</SIMVAR> <UNITS>#VISIBILITY_SIMVAR_UNITS#</UNITS> <SCALE>#VISIBILITY_SIMVAR_SCALE#</SCALE> <BIAS>#VISIBILITY_SIMVAR_BIAS#</BIAS> </ReturnParameters> </ParametersFn>

    Parameters initialization:

    Return parameters:

    Parameters set:

    • SIMVAR (using VISIBILITY_SIMVAR)
    • UNITS (using VISIBILITY_SIMVAR_UNITS)
    • SCALE (using VISIBILITY_SIMVAR_SCALE)
    • BIAS (using VISIBILITY_SIMVAR_BIAS)

    ParametersFn used:

  • ASOBO_Visibility_Code_Base_Parameters

    Definition from XML

    <ParametersFn Name=“ASOBO_Visibility_Code_Base_Parameters”> <Parameters Type=“Default”> <UseParametersFn Name=“ASOBO_Visibility_Base_Default_Parameters”/> </Parameters> <Parameters Type=“Override”> <Condition CheckSavedParameters=“Visibility_Code_Transform_Stack”> <UseParametersFn Name=“ASOBO_Visibility_Code_Transform_Value”> <PLOAD_VISIBILITY_CODE_TRANSFORMS>Visibility_Code_Transform_Stack</PLOAD_VISIBILITY_CODE_TRANSFORMS> </UseParametersFn> </Condition> </Parameters> <ReturnParameters> <UseParametersFn Name=“ASOBO_PFN_Call_Overridable_ParametersFn_Helper”> <PFN_PARAM_DEFAULT>ASOBO_Visibility_Base_Parameters</PFN_PARAM_DEFAULT> <PFN_PARAM_NAME>VISIBILITY_BASE_PARAMETERS_FN</PFN_PARAM_NAME> </UseParametersFn> <CODE>#VISIBILITY_CODE#</CODE> </ReturnParameters> </ParametersFn>

    Parameters initialization:

    Return parameters:

    Parameters set:

    • CODE (using VISIBILITY_CODE)

    ParametersFn used:

  • ASOBO_Visibility_Code_Transform_Value

    Definition from XML

    <ParametersFn Name=“ASOBO_Visibility_Code_Transform_Value”> <Parameters Type=“Override”> <UseParametersFn Name=“ASOBO_Load_Then_Remove_Parameters_Helper”> <SAVED_PARAMETERS>PLOAD_VISIBILITY_CODE_TRANSFORMS</SAVED_PARAMETERS> </UseParametersFn> </Parameters> <ReturnParameters> <Loop> <Setup> <Param>CUR_ID</Param> <From>0</From> <Inc>1</Inc> <While> <Arg Valid=“VISIBILITY_CODE_TRANSFORM_PFN_#CUR_ID#”/> </While> </Setup> <Do> <Parameters Type=“Override”> <VISIBILITY_CODE_TRANSFORM_PFN Process=“Param”>VISIBILITY_CODE_TRANSFORM_PFN_#CUR_ID#</VISIBILITY_CODE_TRANSFORM_PFN> </Parameters> <Parameters Type=“Override” Lifetime=“Loop”> <UseParametersFn Name="#VISIBILITY_CODE_TRANSFORM_PFN#"/> </Parameters> </Do> <Then> <Condition Check=“VISIBILITY_CODE_TRANSFORM_PFN_RETURN”> <True> <UseParametersFn Name="#VISIBILITY_CODE_TRANSFORM_PFN_RETURN#"/> </True> <False> <VISIBILITY_CODE>#VISIBILITY_CODE#</VISIBILITY_CODE> </False> </Condition> </Then> </Loop> </ReturnParameters> </ParametersFn>

    Parameters initialization:

    Return parameters:

    Parameters read:

    • CUR_ID
    • VISIBILITY_CODE_TRANSFORM_PFN

    Parameters set:

    • CUR_ID
    • VISIBILITY_CODE_TRANSFORM_PFN (using CUR_ID)

    ParametersFn used:

    • #VISIBILITY_CODE_TRANSFORM_PFN#

    Condition: Check(VISIBILITY_CODE_TRANSFORM_PFN_RETURN)

    • Case: True

      Parameters read:

      • VISIBILITY_CODE_TRANSFORM_PFN_RETURN

      ParametersFn used:

      • #VISIBILITY_CODE_TRANSFORM_PFN_RETURN#
    • Case: False

      Parameters set:

      • VISIBILITY_CODE (using VISIBILITY_CODE)