# Balloon And Airship Variables The tables below indicate the properties for the [Simulation Variables](../simulation-variables/) that can be used to get and set properties related specifically to **hot air balloons** and **airships**. For information on the units listed for each variable, please see here: [Simulation Variable Units](../simulation-variable-units/) You can find a complete index of all available SimVars here: [SimVar Index](../simulation-variables/#simvar-index) ### Balloon Specific Variables {{< table-wrapper "colclass-2=font-size:0.75rem" "200px" "100px" "" "150px" "100px" >}} | Simulation Variable | Index | Description | Units |Settable | |---|---|---|---|:---:| | {{< anchor id="BALLOON-AUTO-FILL-ACTIVE" />}}`BALLOON AUTO FILL ACTIVE` | N/A | Sets / returns whether the balloon is creating air inside to emulate fans air flow or not. | Boolean| {{< check/good >}} | | {{< anchor id="BALLOON-FILL-AMOUNT" />}}`BALLOON FILL AMOUNT` | N/A | This is used to get / set the ratio of air within the balloon envelope from 0 (empty) to 1 (full). | {{< glossterm >}}percent_over_100{{< /glossterm >}} | {{< check/good >}} | | {{< anchor id="BALLOON-GAS-DENSITY" />}}`BALLOON GAS DENSITY` | N/A | The density of the gas inside the balloon. | {{< glossterm >}}slug{{< /glossterm >}} / ft³ | {{< check/bad >}} | | {{< anchor id="BALLOON-GAS-TEMPERATURE" />}}`BALLOON GAS TEMPERATURE` | N/A | Temperature of the gas inside a balloon. | Rankine| {{< check/good >}} | | {{< anchor id="BALLOON-VENT-OPEN-VALUE" />}}`BALLOON VENT OPEN VALUE` | N/A | This represents how open the "parachute valve" of a hot air balloon is, where 0 is fully closed and 1 is fully open. | {{< glossterm >}}percent_over_100{{< /glossterm >}} | {{< check/good >}} | | {{< anchor id="BURNER-FUEL-FLOW-RATE" />}}`BURNER FUEL FLOW RATE` | Burner Name (or index) | The amount of fuel that is flowing through the named [Burner](../../../content-configuration/cfg-files/system/modular-burner-system-information/#burnern) expressed in {{< glossterm >}}lbs{{< /glossterm >}} per hour. | Number | {{< check/bad >}} | | {{< anchor id="BURNER-HEATING-POWER" />}}`BURNER HEATING POWER` | Burner Name (or index) | This is the thermal power of the named (or indexed) [Burner](../../../content-configuration/cfg-files/system/modular-burner-system-information/#burnern) expressed in {{< glossterm >}}btu{{< /glossterm >}} per hour. If a value of 0 is given instead of a name (or index) then the *sum total of all burners heating power* will be returned. | Number | {{< check/bad >}} | | {{< anchor id="BURNER-PILOT-LIGHT-ON" />}}`BURNER PILOT LIGHT ON` | Burner Name (or index) | The named (or indexed) hot air balloon [Burner](../../../content-configuration/cfg-files/system/modular-burner-system-information/#burnern) pilot light status, where 0 (FALSE) is off, and 1 (TRUE) is on. Note that of the burner is not receiving fuel this SimVar will revert to 0 (FALSE), if set to 1 (TRUE). | Boolean| {{< check/good >}} | | {{< anchor id="BURNER-VALVE-OPEN-VALUE" />}}`BURNER VALVE OPEN VALUE` | Valve Name (or index) | This represents how open the the named (or indexed) burner [Valve](../../../content-configuration/cfg-files/system/modular-burner-system-information/#valven) is, where 0 is fully closed and 1 is fully open. | {{< glossterm >}}percent_over_100{{< /glossterm >}} | {{< check/good >}} | | {{< anchor id="GROUND-ATTACHMENT" />}}`GROUND ATTACHMENT` | N/A | This toggles the status of the attachment rope. When 1 (true) the balloon has an attachment rope, and when 0 (false) it does not. | Boolean| {{< check/good >}} | {{< /table-wrapper >}} ### Airship Specific Variables {{< table-wrapper "colclass-2=font-size:0.75rem" "200px" "100px" "" "150px" "100px" >}} | Simulation Variable | Index | Description | Units | Settable | |---|---|---|---|:---:| | {{< anchor id="AIRSHIP-COMPARTMENT-GAS-TYPE" />}}`AIRSHIP COMPARTMENT GAS TYPE` | Gas Compartment Name (or index) | Gets the type of gas being used by the named (or indexed) [gas compartment](../../../content-configuration/cfg-files/flight_model.cfg/#gas_compartment.N). | Enum:
0:Other
1:Air
2:Helium
3:Hydrogen | {{< check/bad >}} | | {{< anchor id="AIRSHIP-COMPARTMENT-OVERPRESSURE" />}}`AIRSHIP COMPARTMENT OVERPRESSURE` | Gas Compartment Name (or index) | Gets the over-pressure value of the named (or indexed) [gas compartment](../../../content-configuration/cfg-files/flight_model.cfg/#gas_compartment.N).
Note that this value is commonly expressed using {{< glossterm >}}inwg{{< /glossterm >}}, which is not a supported SimVar unit, therfore some conversion may need done on the value before display/use. | Millibars | {{< check/bad >}} | | {{< anchor id="AIRSHIP-COMPARTMENT-PRESSURE" />}}`AIRSHIP COMPARTMENT PRESSURE` | Gas Compartment Name (or index) | Gets the current pressure value of the named (or indexed) [gas compartment](../../../content-configuration/cfg-files/flight_model.cfg/#gas_compartment.N).
Note that this value is commonly expressed using {{< glossterm >}}inwg{{< /glossterm >}}, which is not a supported SimVar unit, therfore some conversion may need done on the value before display/use. | Millibars | {{< check/bad >}} | | {{< anchor id="AIRSHIP-COMPARTMENT-TEMPERATURE" />}}`AIRSHIP COMPARTMENT TEMPERATURE` | Gas Compartment Name (or index) | Gets the current temperature value of the named (or indexed) [gas compartment](../../../content-configuration/cfg-files/flight_model.cfg/#gas_compartment.N). | Celsius | {{< check/bad >}} | | {{< anchor id="AIRSHIP-COMPARTMENT-VOLUME" />}}`AIRSHIP COMPARTMENT VOLUME` | Gas Compartment Name (or index) | Gets the volume of gas in the named (or indexed) [gas compartment](../../../content-configuration/cfg-files/flight_model.cfg/#gas_compartment.N). | Cubic Meter | {{< check/bad >}} | | {{< anchor id="AIRSHIP-COMPARTMENT-WEIGHT" />}}`AIRSHIP COMPARTMENT WEIGHT` | Gas Compartment Name (or index) | Gets the weight of gas in the named (or indexed) [gas compartment](../../../content-configuration/cfg-files/flight_model.cfg/#gas_compartment.N). | {{< glossterm >}}lbs{{< /glossterm >}} | {{< check/bad >}} | | {{< anchor id="AIRSHIP-DAMPER-STATE" />}}`AIRSHIP DAMPER STATE` | Gas Compartment Name (or index) | Gets or sets the state of the named (or indexed) [gas compartment](../../../content-configuration/cfg-files/flight_model.cfg/#gas_compartment.N) damper.
Note that dampers are not defined explicitly, but are added automatically by the simulation, one per-compartment that is of the gas type "Air". Non-air compartments do *not* have dampers. | Enum:
0:Locked
1:Unlocked
2:Forced Open | {{< check/good >}} | | {{< anchor id="AIRSHIP-FAN-POWER-PCT" />}}`AIRSHIP FAN POWER PCT` | Gas Compartment Name (or index) | Gets or sets the state of the air intake fan for the named (or indexed) [gas compartment](../../../content-configuration/cfg-files/flight_model.cfg/#gas_compartment.N).
Note that air intake fans are not defined explicitly, but are added automatically by the simulation, one per-compartment that is of the gas type "Air". Non-air compartments do *not* have air intake fans. | {{< glossterm >}}percent_over_100{{< /glossterm >}} | {{< check/good >}} | | {{< anchor id="AIRSHIP-VALVE-STATE" />}}`AIRSHIP VALVE STATE` | Valve Name (or index) | Gets or sets the state of the named (or indexed) [valve](../../../content-configuration/cfg-files/flight_model.cfg/#valven). | Enum:
0:Locked
1:Unlocked
2:Forced Open | {{< check/good >}} | | {{< anchor id="MAST-TRUCK-DEPLOYMENT" />}}`MAST TRUCK DEPLOYMENT` | N/A | This toggles the status of the mast truck. When 1 (true) the truck should deploy the mast and other stabilisers, and when 0 (false) it should retract the mast and other stabilisers. | Boolean | {{< check/good >}} | | {{< anchor id="MAST-TRUCK-EXTENSION" />}}`MAST TRUCK EXTENSION` | N/A | This is used to get / set the extension value of the mast from the mast truck (which needs to be *deployed* first), where a value of 0 is no extension and a value of 100 is full extension. | Percent | {{< check/good >}} | {{< /table-wrapper >}}