On this page
Balloon_ParametersFn
Asobo_EX1\Common\Interior\Templates\ParametersFn\Balloon_ParametersFn.xml
Source XML
<ModelBehaviors>
<!-- ################################# BALLOON #################################### -->
<!-- ############################################################################## -->
<Include RelativeFile="InteractionPresets\\Balloon_Interactions.xml"/>
<!-- ############################################################################## -->
<ParametersFn Name="ASOBO_Burner_Valve_Parameters">
<Parameters Type="Default">
<VALVE_ID>1</VALVE_ID>
</Parameters>
<Parameters Type="Default">
<VALVE_CLOSE_KEY>(>K:BURNER_VALVE_CLOSE)</VALVE_CLOSE_KEY>
<VALVE_OPEN_KEY>(>K:BURNER_VALVE_OPEN)</VALVE_OPEN_KEY>
<SIMVAR_VALVE>BURNER VALVE OPEN VALUE:#VALVE_ID#</SIMVAR_VALVE>
<SIMVAR_VALVE_UNITS>percent over 100</SIMVAR_VALVE_UNITS>
</Parameters>
<Parameters Type="Default">
<GET_VALVE>(A:#SIMVAR_VALVE#, #SIMVAR_VALVE_UNITS#)</GET_VALVE>
<VALVE_CLOSE_CODE>#VALVE_ID# #VALVE_CLOSE_KEY#</VALVE_CLOSE_CODE>
<VALVE_OPEN_CODE>#VALVE_ID# #VALVE_OPEN_KEY#</VALVE_OPEN_CODE>
</Parameters>
<ReturnParameters>
<SIMVAR_VALVE>#SIMVAR_VALVE#</SIMVAR_VALVE>
<GET_VALVE>#GET_VALVE#</GET_VALVE>
<VALVE_CLOSE_CODE>#VALVE_CLOSE_CODE#</VALVE_CLOSE_CODE>
<VALVE_OPEN_CODE>#VALVE_OPEN_CODE#</VALVE_OPEN_CODE>
</ReturnParameters>
</ParametersFn>
<!-- ############################################################################## -->
<ParametersFn Name="ASOBO_Burner_Igniter_Parameters">
<Parameters Type="Default">
<BURNER_ID>1</BURNER_ID>
</Parameters>
<Parameters Type="Default">
<PILOT_LIGHT_SIMVAR>BURNER PILOT LIGHT ON:#BURNER_ID#</PILOT_LIGHT_SIMVAR>
<PILOT_LIGHT_SIMVAR_UNIT>boolean</PILOT_LIGHT_SIMVAR_UNIT>
</Parameters>
<Parameters Type="Default">
<GET_PILOT_LIGHT>(A:#PILOT_LIGHT_SIMVAR#, #PILOT_LIGHT_SIMVAR_UNIT#)</GET_PILOT_LIGHT>
<SET_PILOT_LIGHT>(>A:#PILOT_LIGHT_SIMVAR#, #PILOT_LIGHT_SIMVAR_UNIT#)</SET_PILOT_LIGHT>
</Parameters>
<ReturnParameters>
<GET_PILOT_LIGHT>#GET_PILOT_LIGHT#</GET_PILOT_LIGHT>
<SET_PILOT_LIGHT>#SET_PILOT_LIGHT#</SET_PILOT_LIGHT>
</ReturnParameters>
</ParametersFn>
<!-- ############################################################################## -->
<ParametersFn Name="ASOBO_Parachute_Valve_Parameters">
<Parameters Type="Default">
<PARACHUTE_VALVE_SIMVAR>BALLOON VENT OPEN VALUE</PARACHUTE_VALVE_SIMVAR><!-- Todo @gdavid : Replace by SimVar -->
<PARACHUTE_VALVE_SIMVAR_UNIT>boolean</PARACHUTE_VALVE_SIMVAR_UNIT>
</Parameters>
<Parameters Type="Default">
<GET_PARACHUTE_VALVE>(A:#PARACHUTE_VALVE_SIMVAR#, #PARACHUTE_VALVE_SIMVAR_UNIT#)</GET_PARACHUTE_VALVE>
<SET_PARACHUTE_VALVE>(>K:BALLOON_VENT_SET)</SET_PARACHUTE_VALVE>
<TOGGLE_PARACHUTE_VALVE>(>K:BALLOON_VENT_TOGGLE)</TOGGLE_PARACHUTE_VALVE>
</Parameters>
<ReturnParameters>
<PARACHUTE_VALVE_SIMVAR>#PARACHUTE_VALVE_SIMVAR#</PARACHUTE_VALVE_SIMVAR>
<GET_PARACHUTE_VALVE>#GET_PARACHUTE_VALVE#</GET_PARACHUTE_VALVE>
<SET_PARACHUTE_VALVE>#SET_PARACHUTE_VALVE#</SET_PARACHUTE_VALVE>
<TOGGLE_PARACHUTE_VALVE>#TOGGLE_PARACHUTE_VALVE#</TOGGLE_PARACHUTE_VALVE>
</ReturnParameters>
</ParametersFn>
</ModelBehaviors>
Includes
- RelativeFile: InteractionPresets\\Balloon_Interactions.xml
ParametersFn
ASOBO_Burner_Valve_Parameters
Definition from XML<ParametersFn Name="ASOBO_Burner_Valve_Parameters"> <Parameters Type="Default"> <VALVE_ID>1</VALVE_ID> </Parameters> <Parameters Type="Default"> <VALVE_CLOSE_KEY>(>K:BURNER_VALVE_CLOSE)</VALVE_CLOSE_KEY> <VALVE_OPEN_KEY>(>K:BURNER_VALVE_OPEN)</VALVE_OPEN_KEY> <SIMVAR_VALVE>BURNER VALVE OPEN VALUE:#VALVE_ID#</SIMVAR_VALVE> <SIMVAR_VALVE_UNITS>percent over 100</SIMVAR_VALVE_UNITS> </Parameters> <Parameters Type="Default"> <GET_VALVE>(A:#SIMVAR_VALVE#, #SIMVAR_VALVE_UNITS#)</GET_VALVE> <VALVE_CLOSE_CODE>#VALVE_ID# #VALVE_CLOSE_KEY#</VALVE_CLOSE_CODE> <VALVE_OPEN_CODE>#VALVE_ID# #VALVE_OPEN_KEY#</VALVE_OPEN_CODE> </Parameters> <ReturnParameters> <SIMVAR_VALVE>#SIMVAR_VALVE#</SIMVAR_VALVE> <GET_VALVE>#GET_VALVE#</GET_VALVE> <VALVE_CLOSE_CODE>#VALVE_CLOSE_CODE#</VALVE_CLOSE_CODE> <VALVE_OPEN_CODE>#VALVE_OPEN_CODE#</VALVE_OPEN_CODE> </ReturnParameters> </ParametersFn>Parameters initialization:
- Default
Parameters set:
- VALVE_ID
- Default
Parameters set:
- VALVE_CLOSE_KEY
- VALVE_OPEN_KEY
- SIMVAR_VALVE (using VALVE_ID)
- SIMVAR_VALVE_UNITS
- Default
Parameters set:
- GET_VALVE (using SIMVAR_VALVE, SIMVAR_VALVE_UNITS)
- VALVE_CLOSE_CODE (using VALVE_ID, VALVE_CLOSE_KEY)
- VALVE_OPEN_CODE (using VALVE_ID, VALVE_OPEN_KEY)
Return parameters:
Parameters set:
- SIMVAR_VALVE (using SIMVAR_VALVE)
- GET_VALVE (using GET_VALVE)
- VALVE_CLOSE_CODE (using VALVE_CLOSE_CODE)
- VALVE_OPEN_CODE (using VALVE_OPEN_CODE)
- Default
ASOBO_Burner_Igniter_Parameters
Definition from XML<ParametersFn Name="ASOBO_Burner_Igniter_Parameters"> <Parameters Type="Default"> <BURNER_ID>1</BURNER_ID> </Parameters> <Parameters Type="Default"> <PILOT_LIGHT_SIMVAR>BURNER PILOT LIGHT ON:#BURNER_ID#</PILOT_LIGHT_SIMVAR> <PILOT_LIGHT_SIMVAR_UNIT>boolean</PILOT_LIGHT_SIMVAR_UNIT> </Parameters> <Parameters Type="Default"> <GET_PILOT_LIGHT>(A:#PILOT_LIGHT_SIMVAR#, #PILOT_LIGHT_SIMVAR_UNIT#)</GET_PILOT_LIGHT> <SET_PILOT_LIGHT>(>A:#PILOT_LIGHT_SIMVAR#, #PILOT_LIGHT_SIMVAR_UNIT#)</SET_PILOT_LIGHT> </Parameters> <ReturnParameters> <GET_PILOT_LIGHT>#GET_PILOT_LIGHT#</GET_PILOT_LIGHT> <SET_PILOT_LIGHT>#SET_PILOT_LIGHT#</SET_PILOT_LIGHT> </ReturnParameters> </ParametersFn>Parameters initialization:
- Default
Parameters set:
- BURNER_ID
- Default
Parameters set:
- PILOT_LIGHT_SIMVAR (using BURNER_ID)
- PILOT_LIGHT_SIMVAR_UNIT
- Default
Parameters set:
- GET_PILOT_LIGHT (using PILOT_LIGHT_SIMVAR, PILOT_LIGHT_SIMVAR_UNIT)
- SET_PILOT_LIGHT (using PILOT_LIGHT_SIMVAR, PILOT_LIGHT_SIMVAR_UNIT)
Return parameters:
Parameters set:
- GET_PILOT_LIGHT (using GET_PILOT_LIGHT)
- SET_PILOT_LIGHT (using SET_PILOT_LIGHT)
- Default
ASOBO_Parachute_Valve_Parameters
Definition from XML<ParametersFn Name="ASOBO_Parachute_Valve_Parameters"> <Parameters Type="Default"> <PARACHUTE_VALVE_SIMVAR>BALLOON VENT OPEN VALUE</PARACHUTE_VALVE_SIMVAR> <PARACHUTE_VALVE_SIMVAR_UNIT>boolean</PARACHUTE_VALVE_SIMVAR_UNIT> </Parameters> <Parameters Type="Default"> <GET_PARACHUTE_VALVE>(A:#PARACHUTE_VALVE_SIMVAR#, #PARACHUTE_VALVE_SIMVAR_UNIT#)</GET_PARACHUTE_VALVE> <SET_PARACHUTE_VALVE>(>K:BALLOON_VENT_SET)</SET_PARACHUTE_VALVE> <TOGGLE_PARACHUTE_VALVE>(>K:BALLOON_VENT_TOGGLE)</TOGGLE_PARACHUTE_VALVE> </Parameters> <ReturnParameters> <PARACHUTE_VALVE_SIMVAR>#PARACHUTE_VALVE_SIMVAR#</PARACHUTE_VALVE_SIMVAR> <GET_PARACHUTE_VALVE>#GET_PARACHUTE_VALVE#</GET_PARACHUTE_VALVE> <SET_PARACHUTE_VALVE>#SET_PARACHUTE_VALVE#</SET_PARACHUTE_VALVE> <TOGGLE_PARACHUTE_VALVE>#TOGGLE_PARACHUTE_VALVE#</TOGGLE_PARACHUTE_VALVE> </ReturnParameters> </ParametersFn>Parameters initialization:
- Default
Parameters set:
- PARACHUTE_VALVE_SIMVAR
- PARACHUTE_VALVE_SIMVAR_UNIT
- Default
Parameters set:
- GET_PARACHUTE_VALVE (using PARACHUTE_VALVE_SIMVAR, PARACHUTE_VALVE_SIMVAR_UNIT)
- SET_PARACHUTE_VALVE
- TOGGLE_PARACHUTE_VALVE
Return parameters:
Parameters set:
- PARACHUTE_VALVE_SIMVAR (using PARACHUTE_VALVE_SIMVAR)
- GET_PARACHUTE_VALVE (using GET_PARACHUTE_VALVE)
- SET_PARACHUTE_VALVE (using SET_PARACHUTE_VALVE)
- TOGGLE_PARACHUTE_VALVE (using TOGGLE_PARACHUTE_VALVE)
- Default
