On this page
Instrument_ParametersFn
Asobo_EX1\Common\Interior\Templates\ParametersFn\Instrument_ParametersFn.xml
Includes
- RelativeFile: InteractionPresets\\Instrument_Interactions.xml
ParametersFn
ASOBO_Instrument_Flag_Animation_Parameters
Definition from XML<ParametersFn Name="ASOBO_Instrument_Flag_Animation_Parameters"> <Parameters Type="Override"> <UseParametersFn Name="ASOBO_Instrument_Failure_Animation_Parameters"/> </Parameters> <ReturnParameters> <SHOW_FLAG_CONDITION>#IS_INSTRUMENT_FAILING#</SHOW_FLAG_CONDITION> </ReturnParameters> </ParametersFn>Parameters initialization:
- Override
ParametersFn used:
Return parameters:
Parameters set:
- SHOW_FLAG_CONDITION (using IS_INSTRUMENT_FAILING)
- Override
ASOBO_Instrument_Failure_Animation_Parameters
Definition from XML<ParametersFn Name="ASOBO_Instrument_Failure_Animation_Parameters"> <Parameters Type="Default"> <INSTRUMENT_TYPE>Pressurized</INSTRUMENT_TYPE> <MIN_VOLTAGE>1</MIN_VOLTAGE> </Parameters> <Parameters Type="Default"> <Switch Param="INSTRUMENT_TYPE"> <Case Value="Pressurized"> <FAILURE>(A:SUCTION PRESSURE, inhg) 2.3 <</FAILURE> </Case> <Case Value="Electrical"> <Condition Check="INSTRUMENT_CIRCUIT_ID"> <True> <FAILURE>(A:CIRCUIT ON:#INSTRUMENT_CIRCUIT_ID#, Bool) !</FAILURE> </True> <False> <FAILURE>(A:ELECTRICAL MAIN BUS VOLTAGE, Volts) #MIN_VOLTAGE# <</FAILURE> </False> </Condition> </Case> </Switch> </Parameters> <ReturnParameters> <IS_INSTRUMENT_FAILING>#FAILURE#</IS_INSTRUMENT_FAILING> <IS_INSTRUMENT_WORKING>#FAILURE# !</IS_INSTRUMENT_WORKING> </ReturnParameters> </ParametersFn>Parameters initialization:
- Default
Parameters set:
- INSTRUMENT_TYPE
- MIN_VOLTAGE
- Default
Condition: Switch(INSTRUMENT_TYPE)
- Case: Pressurized
Parameters set:
- FAILURE
- Case: Electrical
Condition: Check(INSTRUMENT_CIRCUIT_ID)
- Case: True
Parameters set:
- FAILURE (using INSTRUMENT_CIRCUIT_ID)
- Case: False
Parameters set:
- FAILURE (using MIN_VOLTAGE)
Return parameters:
Parameters set:
- IS_INSTRUMENT_FAILING (using FAILURE)
- IS_INSTRUMENT_WORKING (using FAILURE)
- Default
ASOBO_Altimeter_Parameters
Definition from XML<ParametersFn Name="ASOBO_Altimeter_Parameters"> <Parameters Type="Override"> <UseParametersFn Name="ASOBO_Get_Param_Suffix_Helper"/> </Parameters> <Parameters Type="Default"> <ALTIMETER_ID>0</ALTIMETER_ID> </Parameters> <Parameters Type="Default"> <SIMVAR_ALTIMETER_ALTITUDE>INDICATED ALTITUDE:#ALTIMETER_ID#</SIMVAR_ALTIMETER_ALTITUDE> <SIMVAR_RADAR_ALTIMETER_ALTITUDE>PLANE ALT ABOVE GROUND:#ALTIMETER_ID#</SIMVAR_RADAR_ALTIMETER_ALTITUDE> <SIMVAR_ALTIMETER_SETTING>KOHLSMAN SETTING MB:#ALTIMETER_ID#</SIMVAR_ALTIMETER_SETTING> <SIMVAR_ALTIMETER_STANDARD_MODE>KOHLSMAN SETTING STD:#ALTIMETER_ID#</SIMVAR_ALTIMETER_STANDARD_MODE> <UNITS_ALTIMETER_ALTITUDE>Feet</UNITS_ALTIMETER_ALTITUDE> <UNITS_ALTIMETER_SETTING>inHg</UNITS_ALTIMETER_SETTING> </Parameters> <Parameters Type="Default"> <GET_ALTIMETER_ALTITUDE>(A:#SIMVAR_ALTIMETER_ALTITUDE#, #UNITS_ALTIMETER_ALTITUDE#)</GET_ALTIMETER_ALTITUDE> <GET_ALTIMETER_RADAR_ALTITUDE>(A:#SIMVAR_RADAR_ALTIMETER_ALTITUDE#, #UNITS_ALTIMETER_ALTITUDE#)</GET_ALTIMETER_RADAR_ALTITUDE> <GET_ALTIMETER_SETTING>(A:#SIMVAR_ALTIMETER_SETTING#, #UNITS_ALTIMETER_SETTING#)</GET_ALTIMETER_SETTING> <GET_ALTIMETER_SETTING_INHG>(A:#SIMVAR_ALTIMETER_SETTING#, inHg)</GET_ALTIMETER_SETTING_INHG> <GET_ALTIMETER_SETTING_MB>(A:#SIMVAR_ALTIMETER_SETTING#, Millibar)</GET_ALTIMETER_SETTING_MB> <GET_ALTIMETER_STANDARD_MODE>(A:#SIMVAR_ALTIMETER_STANDARD_MODE#, Bool)</GET_ALTIMETER_STANDARD_MODE> </Parameters> <Parameters Type="Default"> <SET_ALTIMETER_ALTITUDE_STD>#ALTIMETER_ID# (>K:BAROMETRIC_STD_PRESSURE)</SET_ALTIMETER_ALTITUDE_STD> <SET_ALTIMETER_STANDARD_MODE>(>A:#SIMVAR_ALTIMETER_STANDARD_MODE#, Bool)</SET_ALTIMETER_STANDARD_MODE> <SET_ALTIMETER_SETTING_MB>sp0 #ALTIMETER_ID# l0 16 * (>K:2:KOHLSMAN_SET)</SET_ALTIMETER_SETTING_MB> <SET_ALTIMETER_SETTING_HG>@inHg_to_millibar sp0 #ALTIMETER_ID# l0 16 * (>K:2:KOHLSMAN_SET)</SET_ALTIMETER_SETTING_HG> </Parameters> <ReturnParameters> <GET_ALTIMETER#OUT_PARAM_SUFFIX#_ALTITUDE>#GET_ALTIMETER_ALTITUDE#</GET_ALTIMETER#OUT_PARAM_SUFFIX#_ALTITUDE> <GET_ALTIMETER#OUT_PARAM_SUFFIX#_RADAR_ALTITUDE>#GET_ALTIMETER_RADAR_ALTITUDE#</GET_ALTIMETER#OUT_PARAM_SUFFIX#_RADAR_ALTITUDE> <GET_ALTIMETER#OUT_PARAM_SUFFIX#_SETTING>#GET_ALTIMETER_SETTING#</GET_ALTIMETER#OUT_PARAM_SUFFIX#_SETTING> <GET_ALTIMETER#OUT_PARAM_SUFFIX#_STANDARD_MODE>#GET_ALTIMETER_STANDARD_MODE#</GET_ALTIMETER#OUT_PARAM_SUFFIX#_STANDARD_MODE> <GET_ALTIMETER#OUT_PARAM_SUFFIX#_SETTING_MB>#GET_ALTIMETER_SETTING_MB#</GET_ALTIMETER#OUT_PARAM_SUFFIX#_SETTING_MB> <GET_ALTIMETER#OUT_PARAM_SUFFIX#_SETTING_INHG>#GET_ALTIMETER_SETTING_INHG#</GET_ALTIMETER#OUT_PARAM_SUFFIX#_SETTING_INHG> <SIMVAR_ALTIMETER#OUT_PARAM_SUFFIX#_ALTITUDE>#SIMVAR_ALTIMETER_ALTITUDE#</SIMVAR_ALTIMETER#OUT_PARAM_SUFFIX#_ALTITUDE> <SIMVAR_ALTIMETER#OUT_PARAM_SUFFIX#_SETTING>#SIMVAR_ALTIMETER_SETTING#</SIMVAR_ALTIMETER#OUT_PARAM_SUFFIX#_SETTING> <SIMVAR_ALTIMETER#OUT_PARAM_SUFFIX#_STANDARD_MODE>#SIMVAR_ALTIMETER_STANDARD_MODE#</SIMVAR_ALTIMETER#OUT_PARAM_SUFFIX#_STANDARD_MODE> <SET_ALTIMETER#OUT_PARAM_SUFFIX#_ALTITUDE_STD>#SET_ALTIMETER_ALTITUDE_STD#</SET_ALTIMETER#OUT_PARAM_SUFFIX#_ALTITUDE_STD> <SET_ALTIMETER#OUT_PARAM_SUFFIX#_STANDARD_MODE>#SET_ALTIMETER_STANDARD_MODE#</SET_ALTIMETER#OUT_PARAM_SUFFIX#_STANDARD_MODE> <SET_ALTIMETER#OUT_PARAM_SUFFIX#_SETTING_MB>#SET_ALTIMETER_SETTING_MB#</SET_ALTIMETER#OUT_PARAM_SUFFIX#_SETTING_MB> <SET_ALTIMETER#OUT_PARAM_SUFFIX#_SETTING_HG>#SET_ALTIMETER_SETTING_HG#</SET_ALTIMETER#OUT_PARAM_SUFFIX#_SETTING_HG> </ReturnParameters> </ParametersFn>Parameters initialization:
- Override
ParametersFn used:
- Default
Parameters set:
- ALTIMETER_ID
- Default
Parameters set:
- SIMVAR_ALTIMETER_ALTITUDE (using ALTIMETER_ID)
- SIMVAR_RADAR_ALTIMETER_ALTITUDE (using ALTIMETER_ID)
- SIMVAR_ALTIMETER_SETTING (using ALTIMETER_ID)
- SIMVAR_ALTIMETER_STANDARD_MODE (using ALTIMETER_ID)
- UNITS_ALTIMETER_ALTITUDE
- UNITS_ALTIMETER_SETTING
- Default
Parameters set:
- GET_ALTIMETER_ALTITUDE (using SIMVAR_ALTIMETER_ALTITUDE, UNITS_ALTIMETER_ALTITUDE)
- GET_ALTIMETER_RADAR_ALTITUDE (using SIMVAR_RADAR_ALTIMETER_ALTITUDE, UNITS_ALTIMETER_ALTITUDE)
- GET_ALTIMETER_SETTING (using SIMVAR_ALTIMETER_SETTING, UNITS_ALTIMETER_SETTING)
- GET_ALTIMETER_SETTING_INHG (using SIMVAR_ALTIMETER_SETTING)
- GET_ALTIMETER_SETTING_MB (using SIMVAR_ALTIMETER_SETTING)
- GET_ALTIMETER_STANDARD_MODE (using SIMVAR_ALTIMETER_STANDARD_MODE)
- Default
Parameters set:
- SET_ALTIMETER_ALTITUDE_STD (using ALTIMETER_ID)
- SET_ALTIMETER_STANDARD_MODE (using SIMVAR_ALTIMETER_STANDARD_MODE)
- SET_ALTIMETER_SETTING_MB (using ALTIMETER_ID)
- SET_ALTIMETER_SETTING_HG (using ALTIMETER_ID)
Return parameters:
Parameters set:
- GET_ALTIMETER#OUT_PARAM_SUFFIX#_ALTITUDE (using GET_ALTIMETER_ALTITUDE)
- GET_ALTIMETER#OUT_PARAM_SUFFIX#_RADAR_ALTITUDE (using GET_ALTIMETER_RADAR_ALTITUDE)
- GET_ALTIMETER#OUT_PARAM_SUFFIX#_SETTING (using GET_ALTIMETER_SETTING)
- GET_ALTIMETER#OUT_PARAM_SUFFIX#_STANDARD_MODE (using GET_ALTIMETER_STANDARD_MODE)
- GET_ALTIMETER#OUT_PARAM_SUFFIX#_SETTING_MB (using GET_ALTIMETER_SETTING_MB)
- GET_ALTIMETER#OUT_PARAM_SUFFIX#_SETTING_INHG (using GET_ALTIMETER_SETTING_INHG)
- SIMVAR_ALTIMETER#OUT_PARAM_SUFFIX#_ALTITUDE (using SIMVAR_ALTIMETER_ALTITUDE)
- SIMVAR_ALTIMETER#OUT_PARAM_SUFFIX#_SETTING (using SIMVAR_ALTIMETER_SETTING)
- SIMVAR_ALTIMETER#OUT_PARAM_SUFFIX#_STANDARD_MODE (using SIMVAR_ALTIMETER_STANDARD_MODE)
- SET_ALTIMETER#OUT_PARAM_SUFFIX#_ALTITUDE_STD (using SET_ALTIMETER_ALTITUDE_STD)
- SET_ALTIMETER#OUT_PARAM_SUFFIX#_STANDARD_MODE (using SET_ALTIMETER_STANDARD_MODE)
- SET_ALTIMETER#OUT_PARAM_SUFFIX#_SETTING_MB (using SET_ALTIMETER_SETTING_MB)
- SET_ALTIMETER#OUT_PARAM_SUFFIX#_SETTING_HG (using SET_ALTIMETER_SETTING_HG)
- Override
ASOBO_Heading_Parameters
Definition from XML<ParametersFn Name="ASOBO_Heading_Parameters"> <Parameters Type="Override"> <UseParametersFn Name="ASOBO_Get_Param_Suffix_Helper"/> </Parameters> <Parameters Type="Default"> <HEADING_ID>1</HEADING_ID> </Parameters> <Parameters Type="Default"> <SIMVAR_HEADING>HEADING INDICATOR:#HEADING_ID#</SIMVAR_HEADING> <UNITS_HEADING>Degrees</UNITS_HEADING> </Parameters> <Parameters Type="Default"> <GET_HEADING>(A:#SIMVAR_HEADING#, #UNITS_HEADING#)</GET_HEADING> </Parameters> <Parameters Type="Default"> <SET_HEADING>dnor (>K:GYRO_DRIFT_SET_EX1)</SET_HEADING> </Parameters> <ReturnParameters> <SIMVAR_HEADING#OUT_PARAM_SUFFIX#>#SIMVAR_HEADING#</SIMVAR_HEADING#OUT_PARAM_SUFFIX#> <GET_HEADING#OUT_PARAM_SUFFIX#>#GET_HEADING#</GET_HEADING#OUT_PARAM_SUFFIX#> <SET_HEADING#OUT_PARAM_SUFFIX#>#SET_HEADING#</SET_HEADING#OUT_PARAM_SUFFIX#> </ReturnParameters> </ParametersFn>Parameters initialization:
- Override
ParametersFn used:
- Default
Parameters set:
- HEADING_ID
- Default
Parameters set:
- SIMVAR_HEADING (using HEADING_ID)
- UNITS_HEADING
- Default
Parameters set:
- GET_HEADING (using SIMVAR_HEADING, UNITS_HEADING)
- Default
Parameters set:
- SET_HEADING
Return parameters:
Parameters set:
- SIMVAR_HEADING#OUT_PARAM_SUFFIX# (using SIMVAR_HEADING)
- GET_HEADING#OUT_PARAM_SUFFIX# (using GET_HEADING)
- SET_HEADING#OUT_PARAM_SUFFIX# (using SET_HEADING)
- Override
ASOBO_Vertical_Speed_Parameters
Definition from XML<ParametersFn Name="ASOBO_Vertical_Speed_Parameters"> <Parameters Type="Default"> <SIMVAR_VERTICAL_SPEED>VERTICAL SPEED</SIMVAR_VERTICAL_SPEED> <UNITS_VERTICAL_SPEED>ft/min</UNITS_VERTICAL_SPEED> </Parameters> <Parameters Type="Default"> <GET_VERTICAL_SPEED>(A:#SIMVAR_VERTICAL_SPEED#, #UNITS_VERTICAL_SPEED#)</GET_VERTICAL_SPEED> </Parameters> <ReturnParameters> <SIMVAR_VERTICAL_SPEED>#SIMVAR_VERTICAL_SPEED#</SIMVAR_VERTICAL_SPEED> <GET_VERTICAL_SPEED>#GET_VERTICAL_SPEED#</GET_VERTICAL_SPEED> </ReturnParameters> </ParametersFn>Parameters initialization:
- Default
Parameters set:
- SIMVAR_VERTICAL_SPEED
- UNITS_VERTICAL_SPEED
- Default
Parameters set:
- GET_VERTICAL_SPEED (using SIMVAR_VERTICAL_SPEED, UNITS_VERTICAL_SPEED)
Return parameters:
Parameters set:
- SIMVAR_VERTICAL_SPEED (using SIMVAR_VERTICAL_SPEED)
- GET_VERTICAL_SPEED (using GET_VERTICAL_SPEED)
- Default
ASOBO_Turn_Coordinator_Parameters
Definition from XML<ParametersFn Name="ASOBO_Turn_Coordinator_Parameters"> <Parameters Type="Default"> <SIMVAR_TURN_COORDINATOR_BALL>TURN COORDINATOR BALL</SIMVAR_TURN_COORDINATOR_BALL> <SIMVAR_TURN_COORDINATOR_BALL_INV>TURN COORDINATOR BALL INV</SIMVAR_TURN_COORDINATOR_BALL_INV> <UNITS_TURN_COORDINATOR_BALL>position</UNITS_TURN_COORDINATOR_BALL> </Parameters> <Parameters Type="Default"> <GET_TURN_COORDINATOR_BALL>(A:#SIMVAR_TURN_COORDINATOR_BALL#, #UNITS_TURN_COORDINATOR_BALL#)</GET_TURN_COORDINATOR_BALL> <GET_TURN_COORDINATOR_BALL_INV>(A:#SIMVAR_TURN_COORDINATOR_BALL_INV#, #UNITS_TURN_COORDINATOR_BALL#)</GET_TURN_COORDINATOR_BALL_INV> </Parameters> <ReturnParameters> <GET_TURN_COORDINATOR_BALL>#GET_TURN_COORDINATOR_BALL#</GET_TURN_COORDINATOR_BALL> <GET_TURN_COORDINATOR_BALL_INV>#GET_TURN_COORDINATOR_BALL_INV#</GET_TURN_COORDINATOR_BALL_INV> <SIMVAR_TURN_COORDINATOR_BALL>#SIMVAR_TURN_COORDINATOR_BALL#</SIMVAR_TURN_COORDINATOR_BALL> <SIMVAR_TURN_COORDINATOR_BALL_INV>#SIMVAR_TURN_COORDINATOR_BALL_INV#</SIMVAR_TURN_COORDINATOR_BALL_INV> </ReturnParameters> </ParametersFn>Parameters initialization:
- Default
Parameters set:
- SIMVAR_TURN_COORDINATOR_BALL
- SIMVAR_TURN_COORDINATOR_BALL_INV
- UNITS_TURN_COORDINATOR_BALL
- Default
Parameters set:
- GET_TURN_COORDINATOR_BALL (using SIMVAR_TURN_COORDINATOR_BALL, UNITS_TURN_COORDINATOR_BALL)
- GET_TURN_COORDINATOR_BALL_INV (using SIMVAR_TURN_COORDINATOR_BALL_INV, UNITS_TURN_COORDINATOR_BALL)
Return parameters:
Parameters set:
- GET_TURN_COORDINATOR_BALL (using GET_TURN_COORDINATOR_BALL)
- GET_TURN_COORDINATOR_BALL_INV (using GET_TURN_COORDINATOR_BALL_INV)
- SIMVAR_TURN_COORDINATOR_BALL (using SIMVAR_TURN_COORDINATOR_BALL)
- SIMVAR_TURN_COORDINATOR_BALL_INV (using SIMVAR_TURN_COORDINATOR_BALL_INV)
- Default
ASOBO_Turn_Indicator_Parameters
Definition from XML<ParametersFn Name="ASOBO_Turn_Indicator_Parameters"> <Parameters Type="Override"> <UseParametersFn Name="ASOBO_Get_Param_Suffix_Helper"/> </Parameters> <Parameters Type="Default"> <TURN_INDICATOR_ID>1</TURN_INDICATOR_ID> </Parameters> <Parameters Type="Default"> <SIMVAR_TURN_INDICATOR_RATE>TURN INDICATOR RATE:#TURN_INDICATOR_ID#</SIMVAR_TURN_INDICATOR_RATE> <UNITS_TURN_INDICATOR_RATE>degree per second</UNITS_TURN_INDICATOR_RATE> </Parameters> <Parameters Type="Default"> <GET_TURN_INDICATOR_RATE>(A:#SIMVAR_TURN_INDICATOR_RATE#, #UNITS_TURN_INDICATOR_RATE#)</GET_TURN_INDICATOR_RATE> </Parameters> <ReturnParameters> <SIMVAR_TURN_INDICATOR_RATE>#SIMVAR_TURN_INDICATOR_RATE#</SIMVAR_TURN_INDICATOR_RATE> <GET_TURN_INDICATOR_RATE>#GET_TURN_INDICATOR_RATE#</GET_TURN_INDICATOR_RATE> </ReturnParameters> </ParametersFn>Parameters initialization:
- Override
ParametersFn used:
- Default
Parameters set:
- TURN_INDICATOR_ID
- Default
Parameters set:
- SIMVAR_TURN_INDICATOR_RATE (using TURN_INDICATOR_ID)
- UNITS_TURN_INDICATOR_RATE
- Default
Parameters set:
- GET_TURN_INDICATOR_RATE (using SIMVAR_TURN_INDICATOR_RATE, UNITS_TURN_INDICATOR_RATE)
Return parameters:
Parameters set:
- SIMVAR_TURN_INDICATOR_RATE (using SIMVAR_TURN_INDICATOR_RATE)
- GET_TURN_INDICATOR_RATE (using GET_TURN_INDICATOR_RATE)
- Override
ASOBO_Attitude_Indicator_Parameters
Definition from XML<ParametersFn Name="ASOBO_Attitude_Indicator_Parameters"> <Parameters Type="Override"> <UseParametersFn Name="ASOBO_Get_Param_Suffix_Helper"/> </Parameters> <Parameters Type="Default"> <INDICATOR_ID>1</INDICATOR_ID> </Parameters> <Parameters Type="Default"> <SIMVAR_ATTITUDE_INDICATOR_PITCH>ATTITUDE INDICATOR PITCH DEGREES</SIMVAR_ATTITUDE_INDICATOR_PITCH> <SIMVAR_ATTITUDE_INDICATOR_BANK>ATTITUDE INDICATOR BANK DEGREES</SIMVAR_ATTITUDE_INDICATOR_BANK> <SIMVAR_ATTITUDE_INDICATOR_BARS>ATTITUDE BARS POSITION</SIMVAR_ATTITUDE_INDICATOR_BARS> <SIMVAR_ATTITUDE_CAGE>ATTITUDE CAGE</SIMVAR_ATTITUDE_CAGE> <UNITS_ATTITUDE_INDICATOR_PITCH>Degrees</UNITS_ATTITUDE_INDICATOR_PITCH> <UNITS_ATTITUDE_INDICATOR_BANK>Degrees</UNITS_ATTITUDE_INDICATOR_BANK> <UNITS_ATTITUDE_INDICATOR_BARS>Percent</UNITS_ATTITUDE_INDICATOR_BARS> </Parameters> <Parameters Type="Default"> <GET_ATTITUDE_INDICATOR_PITCH>(A:#SIMVAR_ATTITUDE_INDICATOR_PITCH#, #UNITS_ATTITUDE_INDICATOR_PITCH#)</GET_ATTITUDE_INDICATOR_PITCH> <GET_ATTITUDE_INDICATOR_BANK>(A:#SIMVAR_ATTITUDE_INDICATOR_BANK#, #UNITS_ATTITUDE_INDICATOR_BANK#)</GET_ATTITUDE_INDICATOR_BANK> <GET_ATTITUDE_INDICATOR_BARS>(A:#SIMVAR_ATTITUDE_INDICATOR_BARS#, #UNITS_ATTITUDE_INDICATOR_BARS#)</GET_ATTITUDE_INDICATOR_BARS> <GET_ATTITUDE_CAGE>(A:#SIMVAR_ATTITUDE_CAGE#, Bool)</GET_ATTITUDE_CAGE> </Parameters> <Parameters Type="Default"> <TOGGLE_ATTITUDE_CAGE>(>K:ATTITUDE_CAGE_BUTTON)</TOGGLE_ATTITUDE_CAGE> <SET_ATTITUDE_CAGE>#GET_ATTITUDE_CAGE# != if{ (>K:ATTITUDE_CAGE_BUTTON) }</SET_ATTITUDE_CAGE> <SET_ATTITUDE_BARS>#INDICATOR_ID# (>K:2:ATTITUDE_BARS_POSITION_SET)</SET_ATTITUDE_BARS> </Parameters> <ReturnParameters> <GET_ATTITUDE_INDICATOR#OUT_PARAM_SUFFIX#_PITCH>#GET_ATTITUDE_INDICATOR_PITCH#</GET_ATTITUDE_INDICATOR#OUT_PARAM_SUFFIX#_PITCH> <GET_ATTITUDE_INDICATOR#OUT_PARAM_SUFFIX#_BANK>#GET_ATTITUDE_INDICATOR_BANK#</GET_ATTITUDE_INDICATOR#OUT_PARAM_SUFFIX#_BANK> <GET_ATTITUDE_INDICATOR#OUT_PARAM_SUFFIX#_BARS>#GET_ATTITUDE_INDICATOR_BARS#</GET_ATTITUDE_INDICATOR#OUT_PARAM_SUFFIX#_BARS> <GET_ATTITUDE#OUT_PARAM_SUFFIX#_CAGE>#GET_ATTITUDE_CAGE#</GET_ATTITUDE#OUT_PARAM_SUFFIX#_CAGE> <SIMVAR_ATTITUDE_INDICATOR#OUT_PARAM_SUFFIX#_PITCH>#SIMVAR_ATTITUDE_INDICATOR_PITCH#</SIMVAR_ATTITUDE_INDICATOR#OUT_PARAM_SUFFIX#_PITCH> <SIMVAR_ATTITUDE_INDICATOR#OUT_PARAM_SUFFIX#_BANK>#SIMVAR_ATTITUDE_INDICATOR_BANK#</SIMVAR_ATTITUDE_INDICATOR#OUT_PARAM_SUFFIX#_BANK> <SIMVAR_ATTITUDE_INDICATOR#OUT_PARAM_SUFFIX#_BARS>#SIMVAR_ATTITUDE_INDICATOR_BARS#</SIMVAR_ATTITUDE_INDICATOR#OUT_PARAM_SUFFIX#_BARS> <SIMVAR_ATTITUDE#OUT_PARAM_SUFFIX#_CAGE>#SIMVAR_ATTITUDE_CAGE#</SIMVAR_ATTITUDE#OUT_PARAM_SUFFIX#_CAGE> <TOGGLE_ATTITUDE#OUT_PARAM_SUFFIX#_CAGE>#TOGGLE_ATTITUDE_CAGE#</TOGGLE_ATTITUDE#OUT_PARAM_SUFFIX#_CAGE> <SET_ATTITUDE#OUT_PARAM_SUFFIX#_CAGE>#SET_ATTITUDE_CAGE#</SET_ATTITUDE#OUT_PARAM_SUFFIX#_CAGE> <SET_ATTITUDE#OUT_PARAM_SUFFIX#_BARS>#SET_ATTITUDE_BARS#</SET_ATTITUDE#OUT_PARAM_SUFFIX#_BARS> </ReturnParameters> </ParametersFn>Parameters initialization:
- Override
ParametersFn used:
- Default
Parameters set:
- INDICATOR_ID
- Default
Parameters set:
- SIMVAR_ATTITUDE_INDICATOR_PITCH
- SIMVAR_ATTITUDE_INDICATOR_BANK
- SIMVAR_ATTITUDE_INDICATOR_BARS
- SIMVAR_ATTITUDE_CAGE
- UNITS_ATTITUDE_INDICATOR_PITCH
- UNITS_ATTITUDE_INDICATOR_BANK
- UNITS_ATTITUDE_INDICATOR_BARS
- Default
Parameters set:
- GET_ATTITUDE_INDICATOR_PITCH (using SIMVAR_ATTITUDE_INDICATOR_PITCH, UNITS_ATTITUDE_INDICATOR_PITCH)
- GET_ATTITUDE_INDICATOR_BANK (using SIMVAR_ATTITUDE_INDICATOR_BANK, UNITS_ATTITUDE_INDICATOR_BANK)
- GET_ATTITUDE_INDICATOR_BARS (using SIMVAR_ATTITUDE_INDICATOR_BARS, UNITS_ATTITUDE_INDICATOR_BARS)
- GET_ATTITUDE_CAGE (using SIMVAR_ATTITUDE_CAGE)
- Default
Parameters set:
- TOGGLE_ATTITUDE_CAGE
- SET_ATTITUDE_CAGE (using GET_ATTITUDE_CAGE)
- SET_ATTITUDE_BARS (using INDICATOR_ID)
Return parameters:
Parameters set:
- GET_ATTITUDE_INDICATOR#OUT_PARAM_SUFFIX#_PITCH (using GET_ATTITUDE_INDICATOR_PITCH)
- GET_ATTITUDE_INDICATOR#OUT_PARAM_SUFFIX#_BANK (using GET_ATTITUDE_INDICATOR_BANK)
- GET_ATTITUDE_INDICATOR#OUT_PARAM_SUFFIX#_BARS (using GET_ATTITUDE_INDICATOR_BARS)
- GET_ATTITUDE#OUT_PARAM_SUFFIX#_CAGE (using GET_ATTITUDE_CAGE)
- SIMVAR_ATTITUDE_INDICATOR#OUT_PARAM_SUFFIX#_PITCH (using SIMVAR_ATTITUDE_INDICATOR_PITCH)
- SIMVAR_ATTITUDE_INDICATOR#OUT_PARAM_SUFFIX#_BANK (using SIMVAR_ATTITUDE_INDICATOR_BANK)
- SIMVAR_ATTITUDE_INDICATOR#OUT_PARAM_SUFFIX#_BARS (using SIMVAR_ATTITUDE_INDICATOR_BARS)
- SIMVAR_ATTITUDE#OUT_PARAM_SUFFIX#_CAGE (using SIMVAR_ATTITUDE_CAGE)
- TOGGLE_ATTITUDE#OUT_PARAM_SUFFIX#_CAGE (using TOGGLE_ATTITUDE_CAGE)
- SET_ATTITUDE#OUT_PARAM_SUFFIX#_CAGE (using SET_ATTITUDE_CAGE)
- SET_ATTITUDE#OUT_PARAM_SUFFIX#_BARS (using SET_ATTITUDE_BARS)
- Override
ASOBO_Hourmeter_Parameters
Definition from XML<ParametersFn Name="ASOBO_Hourmeter_Parameters"> <Parameters Type="Override"> <UseParametersFn Name="ASOBO_Get_Param_Suffix_Helper"/> </Parameters> <Parameters Type="Default"> <ENG_ID>1</ENG_ID> </Parameters> <Parameters Type="Default"> <SIMVAR_ELAPSED_ENG_HOBBS_TIME>GENERAL ENG ELAPSED HOBBS TIME:#ENG_ID#</SIMVAR_ELAPSED_ENG_HOBBS_TIME> <SIMVAR_ELAPSED_ENG_TIME>GENERAL ENG ELAPSED TIME:#ENG_ID#</SIMVAR_ELAPSED_ENG_TIME> <UNITS_TIME>Hours</UNITS_TIME> </Parameters> <Parameters Type="Default"> <GET_ELAPSED_ENG_HOBBS_TIME>(A:#SIMVAR_ELAPSED_ENG_HOBBS_TIME#, #UNITS_TIME#)</GET_ELAPSED_ENG_HOBBS_TIME> <GET_ELAPSED_ENG_TIME>(A:#SIMVAR_ELAPSED_ENG_TIME#, #UNITS_TIME#)</GET_ELAPSED_ENG_TIME> </Parameters> <ReturnParameters> <SIMVAR_ELAPSED_ENG#OUT_PARAM_SUFFIX#_HOBBS_TIME>#SIMVAR_ELAPSED_ENG_HOBBS_TIME#</SIMVAR_ELAPSED_ENG#OUT_PARAM_SUFFIX#_HOBBS_TIME> <SIMVAR_ELAPSED_ENG#OUT_PARAM_SUFFIX#_TIME>#SIMVAR_ELAPSED_ENG_TIME#</SIMVAR_ELAPSED_ENG#OUT_PARAM_SUFFIX#_TIME> <GET_ELAPSED_ENG#OUT_PARAM_SUFFIX#_HOBBS_TIME>#GET_ELAPSED_ENG_HOBBS_TIME#</GET_ELAPSED_ENG#OUT_PARAM_SUFFIX#_HOBBS_TIME> <GET_ELAPSED_ENG#OUT_PARAM_SUFFIX#_TIME>#GET_ELAPSED_ENG_TIME#</GET_ELAPSED_ENG#OUT_PARAM_SUFFIX#_TIME> </ReturnParameters> </ParametersFn>Parameters initialization:
- Override
ParametersFn used:
- Default
Parameters set:
- ENG_ID
- Default
Parameters set:
- SIMVAR_ELAPSED_ENG_HOBBS_TIME (using ENG_ID)
- SIMVAR_ELAPSED_ENG_TIME (using ENG_ID)
- UNITS_TIME
- Default
Parameters set:
- GET_ELAPSED_ENG_HOBBS_TIME (using SIMVAR_ELAPSED_ENG_HOBBS_TIME, UNITS_TIME)
- GET_ELAPSED_ENG_TIME (using SIMVAR_ELAPSED_ENG_TIME, UNITS_TIME)
Return parameters:
Parameters set:
- SIMVAR_ELAPSED_ENG#OUT_PARAM_SUFFIX#_HOBBS_TIME (using SIMVAR_ELAPSED_ENG_HOBBS_TIME)
- SIMVAR_ELAPSED_ENG#OUT_PARAM_SUFFIX#_TIME (using SIMVAR_ELAPSED_ENG_TIME)
- GET_ELAPSED_ENG#OUT_PARAM_SUFFIX#_HOBBS_TIME (using GET_ELAPSED_ENG_HOBBS_TIME)
- GET_ELAPSED_ENG#OUT_PARAM_SUFFIX#_TIME (using GET_ELAPSED_ENG_TIME)
- Override
ASOBO_Compass_Parameters
Definition from XML<ParametersFn Name="ASOBO_Compass_Parameters"> <Parameters Type="Default"> <SIMVAR_COMPASS>WISKEY COMPASS INDICATION DEGREES</SIMVAR_COMPASS> <UNITS_COMPASS>Degrees</UNITS_COMPASS> </Parameters> <Parameters Type="Default"> <GET_COMPASS>(A:#SIMVAR_COMPASS#, #UNITS_COMPASS#)</GET_COMPASS> </Parameters> <ReturnParameters> <SIMVAR_COMPASS>#SIMVAR_COMPASS#</SIMVAR_COMPASS> <GET_COMPASS>#GET_COMPASS#</GET_COMPASS> </ReturnParameters> </ParametersFn>Parameters initialization:
- Default
Parameters set:
- SIMVAR_COMPASS
- UNITS_COMPASS
- Default
Parameters set:
- GET_COMPASS (using SIMVAR_COMPASS, UNITS_COMPASS)
Return parameters:
Parameters set:
- SIMVAR_COMPASS (using SIMVAR_COMPASS)
- GET_COMPASS (using GET_COMPASS)
- Default
ASOBO_Compass_Bank_Parameters
Definition from XML<ParametersFn Name="ASOBO_Compass_Bank_Parameters"> <Parameters Type="Default"> <SIMVAR_COMPASS>PLANE BANK DEGREES</SIMVAR_COMPASS> <UNITS_COMPASS>Degrees</UNITS_COMPASS> </Parameters> <Parameters Type="Default"> <GET_COMPASS>(A:#SIMVAR_COMPASS#, #UNITS_COMPASS#)</GET_COMPASS> </Parameters> <ReturnParameters> <SIMVAR_COMPASS_BANK>#SIMVAR_COMPASS#</SIMVAR_COMPASS_BANK> <GET_COMPASS_BANK>#GET_COMPASS#</GET_COMPASS_BANK> </ReturnParameters> </ParametersFn>Parameters initialization:
- Default
Parameters set:
- SIMVAR_COMPASS
- UNITS_COMPASS
- Default
Parameters set:
- GET_COMPASS (using SIMVAR_COMPASS, UNITS_COMPASS)
Return parameters:
Parameters set:
- SIMVAR_COMPASS_BANK (using SIMVAR_COMPASS)
- GET_COMPASS_BANK (using GET_COMPASS)
- Default
ASOBO_Compass_Pitch_Parameters
Definition from XML<ParametersFn Name="ASOBO_Compass_Pitch_Parameters"> <Parameters Type="Default"> <SIMVAR_COMPASS>PLANE PITCH DEGREES</SIMVAR_COMPASS> <UNITS_COMPASS>Degrees</UNITS_COMPASS> </Parameters> <Parameters Type="Default"> <GET_COMPASS>(A:#SIMVAR_COMPASS#, #UNITS_COMPASS#)</GET_COMPASS> </Parameters> <ReturnParameters> <SIMVAR_COMPASS_PITCH>#SIMVAR_COMPASS#</SIMVAR_COMPASS_PITCH> <GET_COMPASS_PITCH>#GET_COMPASS#</GET_COMPASS_PITCH> </ReturnParameters> </ParametersFn>Parameters initialization:
- Default
Parameters set:
- SIMVAR_COMPASS
- UNITS_COMPASS
- Default
Parameters set:
- GET_COMPASS (using SIMVAR_COMPASS, UNITS_COMPASS)
Return parameters:
Parameters set:
- SIMVAR_COMPASS_PITCH (using SIMVAR_COMPASS)
- GET_COMPASS_PITCH (using GET_COMPASS)
- Default
ASOBO_Fuel_Pressure_Parameters
Definition from XML<ParametersFn Name="ASOBO_Fuel_Pressure_Parameters"> <Parameters Type="Default"> <ID>1</ID> </Parameters> <Parameters Type="Default"> <LINE_SIMVAR>FUELSYSTEM LINE FUEL PRESSURE</LINE_SIMVAR> <LINE_SIMVAR_UNITS>PSI</LINE_SIMVAR_UNITS> <LINE_ID>#ID#</LINE_ID> </Parameters> <Parameters Type="Default"> <SIMVAR_PRESSURE>#LINE_SIMVAR#:#LINE_ID#</SIMVAR_PRESSURE> </Parameters> <Parameters Type="Default"> <GET_PRESSURE>(A:#SIMVAR_PRESSURE#, #LINE_SIMVAR_UNITS#)</GET_PRESSURE> </Parameters> <ReturnParameters> <SIMVAR_PRESSURE>#SIMVAR_PRESSURE#</SIMVAR_PRESSURE> <GET_PRESSURE>#GET_PRESSURE#</GET_PRESSURE> </ReturnParameters> </ParametersFn>Parameters initialization:
- Default
Parameters set:
- ID
- Default
Parameters set:
- LINE_SIMVAR
- LINE_SIMVAR_UNITS
- LINE_ID (using ID)
- Default
Parameters set:
- SIMVAR_PRESSURE (using LINE_SIMVAR, LINE_ID)
- Default
Parameters set:
- GET_PRESSURE (using SIMVAR_PRESSURE, LINE_SIMVAR_UNITS)
Return parameters:
Parameters set:
- SIMVAR_PRESSURE (using SIMVAR_PRESSURE)
- GET_PRESSURE (using GET_PRESSURE)
- Default
