[Go back to index]

Asobo_EX1\Common\Interior\Templates\ParametersFn\InteractionPresets\Balloon_Interactions.xml

Source XML
<ModelBehaviors> <!-- ################################# BALLOON #################################### --> <!-- ############################################################################## --> <ParametersFn Name="Asobo_Burner_Valve_Settings_Config"> <Parameters Type="Default"> <VALVE_ID>1</VALVE_ID> </Parameters> <Parameters Type="Override"> <UseParametersFn Name="ASOBO_Burner_Valve_Parameters"/> </Parameters> <ReturnParameters> <UseParametersFn Name="ASOBO_Add_Set_Binding_Helper"> <ALIAS_ID>SetOpen</ALIAS_ID> <PARAM_0>1 (&gt;O:_Interaction_Is_Locked) 1</PARAM_0> <PARAM_0_IS_DYNAMIC>True</PARAM_0_IS_DYNAMIC> </UseParametersFn> <UseParametersFn Name="ASOBO_Add_Set_Binding_Helper"> <ALIAS_ID>SetClose</ALIAS_ID> <PARAM_0>0 (&gt;O:_Interaction_Is_Locked) 0</PARAM_0> <PARAM_0_IS_DYNAMIC>True</PARAM_0_IS_DYNAMIC> </UseParametersFn> <UseParametersFn Name="ASOBO_Auto_Define_XStates_Variant_Helper"/> <UseParametersFn Name="ASOBO_Watch_Simvar_Helper"> <SIMVAR>#SIMVAR_VALVE#</SIMVAR> </UseParametersFn> <!-- Check position --> <POS_CLOSED_CHECK>#GET_VALVE# 0 ==</POS_CLOSED_CHECK> <POS_OPEN_CHECK>#GET_VALVE# 0 &gt;</POS_OPEN_CHECK> <!-- Set position --> <POS_CLOSED_CODE>#VALVE_CLOSE_CODE#</POS_CLOSED_CODE> <POS_OPEN_CODE>#VALVE_OPEN_CODE#</POS_OPEN_CODE> </ReturnParameters> </ParametersFn> <!-- ############################################################################## --> <ParametersFn Name="Asobo_Burner_Igniter_Settings_Config"> <Parameters Type="Default"> <BURNER_ID>1</BURNER_ID> </Parameters> <Parameters Type="Override"> <UseParametersFn Name="ASOBO_Burner_Igniter_Parameters"/> </Parameters> <ReturnParameters> <ON_EVENT>1 #SET_PILOT_LIGHT#</ON_EVENT> <ON_RELEASE>1 #SET_PILOT_LIGHT#</ON_RELEASE> </ReturnParameters> </ParametersFn> <!-- ############################################################################## --> <ParametersFn Name="Asobo_Parachute_Valve_Settings_Config"> <Parameters Type="Override"> <UseParametersFn Name="ASOBO_Parachute_Valve_Parameters"/> </Parameters> <ReturnParameters> <UseParametersFn Name="ASOBO_Auto_Define_XStates_Variant_Helper"/> <UseParametersFn Name="ASOBO_Watch_Simvar_Helper"> <SIMVAR>#PARACHUTE_VALVE_SIMVAR#</SIMVAR> </UseParametersFn> <UseParametersFn Name="ASOBO_Add_Set_Binding_Helper"> <ALIAS_ID>Pull</ALIAS_ID> <PARAM_0>1 (&gt;O:_Interaction_Is_Locked) @16k</PARAM_0> <PARAM_0_IS_DYNAMIC>True</PARAM_0_IS_DYNAMIC> </UseParametersFn> <UseParametersFn Name="ASOBO_Add_Set_Binding_Helper"> <ALIAS_ID>Release</ALIAS_ID> <PARAM_0>0 (&gt;O:_Interaction_Is_Locked) 0</PARAM_0> <PARAM_0_IS_DYNAMIC>True</PARAM_0_IS_DYNAMIC> </UseParametersFn> <!-- Check position --> <POS_CLOSED_CHECK>#GET_PARACHUTE_VALVE# 0 ==</POS_CLOSED_CHECK> <POS_OPEN_CHECK>#GET_PARACHUTE_VALVE# 0 &gt;</POS_OPEN_CHECK> <!-- Set position --> <POS_CLOSED_CODE>0 #SET_PARACHUTE_VALVE#</POS_CLOSED_CODE> <POS_OPEN_CODE>@16K #SET_PARACHUTE_VALVE#</POS_OPEN_CODE> </ReturnParameters> </ParametersFn> <!-- ############################################################################## --> </ModelBehaviors>

 

 

ParametersFn

  • Asobo_Burner_Valve_Settings_Config

    Definition from XML
    <ParametersFn Name="Asobo_Burner_Valve_Settings_Config"> <Parameters Type="Default"> <VALVE_ID>1</VALVE_ID> </Parameters> <Parameters Type="Override"> <UseParametersFn Name="ASOBO_Burner_Valve_Parameters"/> </Parameters> <ReturnParameters> <UseParametersFn Name="ASOBO_Add_Set_Binding_Helper"> <ALIAS_ID>SetOpen</ALIAS_ID> <PARAM_0>1 (&gt;O:_Interaction_Is_Locked) 1</PARAM_0> <PARAM_0_IS_DYNAMIC>True</PARAM_0_IS_DYNAMIC> </UseParametersFn> <UseParametersFn Name="ASOBO_Add_Set_Binding_Helper"> <ALIAS_ID>SetClose</ALIAS_ID> <PARAM_0>0 (&gt;O:_Interaction_Is_Locked) 0</PARAM_0> <PARAM_0_IS_DYNAMIC>True</PARAM_0_IS_DYNAMIC> </UseParametersFn> <UseParametersFn Name="ASOBO_Auto_Define_XStates_Variant_Helper"/> <UseParametersFn Name="ASOBO_Watch_Simvar_Helper"> <SIMVAR>#SIMVAR_VALVE#</SIMVAR> </UseParametersFn> <POS_CLOSED_CHECK>#GET_VALVE# 0 ==</POS_CLOSED_CHECK> <POS_OPEN_CHECK>#GET_VALVE# 0 &gt;</POS_OPEN_CHECK> <POS_CLOSED_CODE>#VALVE_CLOSE_CODE#</POS_CLOSED_CODE> <POS_OPEN_CODE>#VALVE_OPEN_CODE#</POS_OPEN_CODE> </ReturnParameters> </ParametersFn>

    Parameters initialization:

    Return parameters:

    Parameters set:

    • POS_CLOSED_CHECK (using GET_VALVE)
    • POS_OPEN_CHECK (using GET_VALVE)
    • POS_CLOSED_CODE (using VALVE_CLOSE_CODE)
    • POS_OPEN_CODE (using VALVE_OPEN_CODE)

    ParametersFn used:

  • Asobo_Burner_Igniter_Settings_Config

    Definition from XML
    <ParametersFn Name="Asobo_Burner_Igniter_Settings_Config"> <Parameters Type="Default"> <BURNER_ID>1</BURNER_ID> </Parameters> <Parameters Type="Override"> <UseParametersFn Name="ASOBO_Burner_Igniter_Parameters"/> </Parameters> <ReturnParameters> <ON_EVENT>1 #SET_PILOT_LIGHT#</ON_EVENT> <ON_RELEASE>1 #SET_PILOT_LIGHT#</ON_RELEASE> </ReturnParameters> </ParametersFn>

    Parameters initialization:

    Return parameters:

    Parameters set:

    • ON_EVENT (using SET_PILOT_LIGHT)
    • ON_RELEASE (using SET_PILOT_LIGHT)
  • Asobo_Parachute_Valve_Settings_Config

    Definition from XML
    <ParametersFn Name="Asobo_Parachute_Valve_Settings_Config"> <Parameters Type="Override"> <UseParametersFn Name="ASOBO_Parachute_Valve_Parameters"/> </Parameters> <ReturnParameters> <UseParametersFn Name="ASOBO_Auto_Define_XStates_Variant_Helper"/> <UseParametersFn Name="ASOBO_Watch_Simvar_Helper"> <SIMVAR>#PARACHUTE_VALVE_SIMVAR#</SIMVAR> </UseParametersFn> <UseParametersFn Name="ASOBO_Add_Set_Binding_Helper"> <ALIAS_ID>Pull</ALIAS_ID> <PARAM_0>1 (&gt;O:_Interaction_Is_Locked) @16k</PARAM_0> <PARAM_0_IS_DYNAMIC>True</PARAM_0_IS_DYNAMIC> </UseParametersFn> <UseParametersFn Name="ASOBO_Add_Set_Binding_Helper"> <ALIAS_ID>Release</ALIAS_ID> <PARAM_0>0 (&gt;O:_Interaction_Is_Locked) 0</PARAM_0> <PARAM_0_IS_DYNAMIC>True</PARAM_0_IS_DYNAMIC> </UseParametersFn> <POS_CLOSED_CHECK>#GET_PARACHUTE_VALVE# 0 ==</POS_CLOSED_CHECK> <POS_OPEN_CHECK>#GET_PARACHUTE_VALVE# 0 &gt;</POS_OPEN_CHECK> <POS_CLOSED_CODE>0 #SET_PARACHUTE_VALVE#</POS_CLOSED_CODE> <POS_OPEN_CODE>@16K #SET_PARACHUTE_VALVE#</POS_OPEN_CODE> </ReturnParameters> </ParametersFn>

    Parameters initialization:

    Return parameters:

    Parameters set:

    • POS_CLOSED_CHECK (using GET_PARACHUTE_VALVE)
    • POS_OPEN_CHECK (using GET_PARACHUTE_VALVE)
    • POS_CLOSED_CODE (using SET_PARACHUTE_VALVE)
    • POS_OPEN_CODE (using SET_PARACHUTE_VALVE)

    ParametersFn used:

 

0/255