On this page
Balloon_Interactions
Asobo_EX1\Common\Interior\Templates\ParametersFn\InteractionPresets\Balloon_Interactions.xml
Source XML
<ModelBehaviors>
<!-- ################################# BALLOON #################################### -->
<!-- ############################################################################## -->
<ParametersFn Name="Asobo_Burner_Valve_Settings_Config">
<Parameters Type="Default">
<VALVE_ID>1</VALVE_ID>
</Parameters>
<Parameters Type="Override">
<UseParametersFn Name="ASOBO_Burner_Valve_Parameters"/>
</Parameters>
<ReturnParameters>
<UseParametersFn Name="ASOBO_Add_Set_Binding_Helper">
<ALIAS_ID>SetOpen</ALIAS_ID>
<PARAM_0>1 (>O:_Interaction_Is_Locked) 1</PARAM_0>
<PARAM_0_IS_DYNAMIC>True</PARAM_0_IS_DYNAMIC>
</UseParametersFn>
<UseParametersFn Name="ASOBO_Add_Set_Binding_Helper">
<ALIAS_ID>SetClose</ALIAS_ID>
<PARAM_0>0 (>O:_Interaction_Is_Locked) 0</PARAM_0>
<PARAM_0_IS_DYNAMIC>True</PARAM_0_IS_DYNAMIC>
</UseParametersFn>
<UseParametersFn Name="ASOBO_Auto_Define_XStates_Variant_Helper"/>
<UseParametersFn Name="ASOBO_Watch_Simvar_Helper">
<SIMVAR>#SIMVAR_VALVE#</SIMVAR>
</UseParametersFn>
<!-- Check position -->
<POS_CLOSED_CHECK>#GET_VALVE# 0 ==</POS_CLOSED_CHECK>
<POS_OPEN_CHECK>#GET_VALVE# 0 ></POS_OPEN_CHECK>
<!-- Set position -->
<POS_CLOSED_CODE>#VALVE_CLOSE_CODE#</POS_CLOSED_CODE>
<POS_OPEN_CODE>#VALVE_OPEN_CODE#</POS_OPEN_CODE>
</ReturnParameters>
</ParametersFn>
<!-- ############################################################################## -->
<ParametersFn Name="Asobo_Burner_Igniter_Settings_Config">
<Parameters Type="Default">
<BURNER_ID>1</BURNER_ID>
</Parameters>
<Parameters Type="Override">
<UseParametersFn Name="ASOBO_Burner_Igniter_Parameters"/>
</Parameters>
<ReturnParameters>
<ON_EVENT>1 #SET_PILOT_LIGHT#</ON_EVENT>
<ON_RELEASE>1 #SET_PILOT_LIGHT#</ON_RELEASE>
</ReturnParameters>
</ParametersFn>
<!-- ############################################################################## -->
<ParametersFn Name="Asobo_Parachute_Valve_Settings_Config">
<Parameters Type="Override">
<UseParametersFn Name="ASOBO_Parachute_Valve_Parameters"/>
</Parameters>
<ReturnParameters>
<UseParametersFn Name="ASOBO_Auto_Define_XStates_Variant_Helper"/>
<UseParametersFn Name="ASOBO_Watch_Simvar_Helper">
<SIMVAR>#PARACHUTE_VALVE_SIMVAR#</SIMVAR>
</UseParametersFn>
<UseParametersFn Name="ASOBO_Add_Set_Binding_Helper">
<ALIAS_ID>Pull</ALIAS_ID>
<PARAM_0>1 (>O:_Interaction_Is_Locked) @16k</PARAM_0>
<PARAM_0_IS_DYNAMIC>True</PARAM_0_IS_DYNAMIC>
</UseParametersFn>
<UseParametersFn Name="ASOBO_Add_Set_Binding_Helper">
<ALIAS_ID>Release</ALIAS_ID>
<PARAM_0>0 (>O:_Interaction_Is_Locked) 0</PARAM_0>
<PARAM_0_IS_DYNAMIC>True</PARAM_0_IS_DYNAMIC>
</UseParametersFn>
<!-- Check position -->
<POS_CLOSED_CHECK>#GET_PARACHUTE_VALVE# 0 ==</POS_CLOSED_CHECK>
<POS_OPEN_CHECK>#GET_PARACHUTE_VALVE# 0 ></POS_OPEN_CHECK>
<!-- Set position -->
<POS_CLOSED_CODE>0 #SET_PARACHUTE_VALVE#</POS_CLOSED_CODE>
<POS_OPEN_CODE>@16K #SET_PARACHUTE_VALVE#</POS_OPEN_CODE>
</ReturnParameters>
</ParametersFn>
<!-- ############################################################################## -->
</ModelBehaviors>
ParametersFn
Asobo_Burner_Valve_Settings_Config
Definition from XML<ParametersFn Name="Asobo_Burner_Valve_Settings_Config"> <Parameters Type="Default"> <VALVE_ID>1</VALVE_ID> </Parameters> <Parameters Type="Override"> <UseParametersFn Name="ASOBO_Burner_Valve_Parameters"/> </Parameters> <ReturnParameters> <UseParametersFn Name="ASOBO_Add_Set_Binding_Helper"> <ALIAS_ID>SetOpen</ALIAS_ID> <PARAM_0>1 (>O:_Interaction_Is_Locked) 1</PARAM_0> <PARAM_0_IS_DYNAMIC>True</PARAM_0_IS_DYNAMIC> </UseParametersFn> <UseParametersFn Name="ASOBO_Add_Set_Binding_Helper"> <ALIAS_ID>SetClose</ALIAS_ID> <PARAM_0>0 (>O:_Interaction_Is_Locked) 0</PARAM_0> <PARAM_0_IS_DYNAMIC>True</PARAM_0_IS_DYNAMIC> </UseParametersFn> <UseParametersFn Name="ASOBO_Auto_Define_XStates_Variant_Helper"/> <UseParametersFn Name="ASOBO_Watch_Simvar_Helper"> <SIMVAR>#SIMVAR_VALVE#</SIMVAR> </UseParametersFn> <POS_CLOSED_CHECK>#GET_VALVE# 0 ==</POS_CLOSED_CHECK> <POS_OPEN_CHECK>#GET_VALVE# 0 ></POS_OPEN_CHECK> <POS_CLOSED_CODE>#VALVE_CLOSE_CODE#</POS_CLOSED_CODE> <POS_OPEN_CODE>#VALVE_OPEN_CODE#</POS_OPEN_CODE> </ReturnParameters> </ParametersFn>Parameters initialization:
- Default
Parameters set:
- VALVE_ID
- Override
ParametersFn used:
Return parameters:
Parameters set:
- POS_CLOSED_CHECK (using GET_VALVE)
- POS_OPEN_CHECK (using GET_VALVE)
- POS_CLOSED_CODE (using VALVE_CLOSE_CODE)
- POS_OPEN_CODE (using VALVE_OPEN_CODE)
ParametersFn used:
- ASOBO_Add_Set_Binding_Helper
Parameters set:
- ALIAS_ID
- PARAM_0
- PARAM_0_IS_DYNAMIC
- ASOBO_Add_Set_Binding_Helper
Parameters set:
- ALIAS_ID
- PARAM_0
- PARAM_0_IS_DYNAMIC
- ASOBO_Auto_Define_XStates_Variant_Helper
- ASOBO_Watch_Simvar_Helper
Parameters set:
- SIMVAR (using SIMVAR_VALVE)
- Default
Asobo_Burner_Igniter_Settings_Config
Definition from XML<ParametersFn Name="Asobo_Burner_Igniter_Settings_Config"> <Parameters Type="Default"> <BURNER_ID>1</BURNER_ID> </Parameters> <Parameters Type="Override"> <UseParametersFn Name="ASOBO_Burner_Igniter_Parameters"/> </Parameters> <ReturnParameters> <ON_EVENT>1 #SET_PILOT_LIGHT#</ON_EVENT> <ON_RELEASE>1 #SET_PILOT_LIGHT#</ON_RELEASE> </ReturnParameters> </ParametersFn>Parameters initialization:
- Default
Parameters set:
- BURNER_ID
- Override
ParametersFn used:
Return parameters:
Parameters set:
- ON_EVENT (using SET_PILOT_LIGHT)
- ON_RELEASE (using SET_PILOT_LIGHT)
- Default
Asobo_Parachute_Valve_Settings_Config
Definition from XML<ParametersFn Name="Asobo_Parachute_Valve_Settings_Config"> <Parameters Type="Override"> <UseParametersFn Name="ASOBO_Parachute_Valve_Parameters"/> </Parameters> <ReturnParameters> <UseParametersFn Name="ASOBO_Auto_Define_XStates_Variant_Helper"/> <UseParametersFn Name="ASOBO_Watch_Simvar_Helper"> <SIMVAR>#PARACHUTE_VALVE_SIMVAR#</SIMVAR> </UseParametersFn> <UseParametersFn Name="ASOBO_Add_Set_Binding_Helper"> <ALIAS_ID>Pull</ALIAS_ID> <PARAM_0>1 (>O:_Interaction_Is_Locked) @16k</PARAM_0> <PARAM_0_IS_DYNAMIC>True</PARAM_0_IS_DYNAMIC> </UseParametersFn> <UseParametersFn Name="ASOBO_Add_Set_Binding_Helper"> <ALIAS_ID>Release</ALIAS_ID> <PARAM_0>0 (>O:_Interaction_Is_Locked) 0</PARAM_0> <PARAM_0_IS_DYNAMIC>True</PARAM_0_IS_DYNAMIC> </UseParametersFn> <POS_CLOSED_CHECK>#GET_PARACHUTE_VALVE# 0 ==</POS_CLOSED_CHECK> <POS_OPEN_CHECK>#GET_PARACHUTE_VALVE# 0 ></POS_OPEN_CHECK> <POS_CLOSED_CODE>0 #SET_PARACHUTE_VALVE#</POS_CLOSED_CODE> <POS_OPEN_CODE>@16K #SET_PARACHUTE_VALVE#</POS_OPEN_CODE> </ReturnParameters> </ParametersFn>Parameters initialization:
- Override
ParametersFn used:
Return parameters:
Parameters set:
- POS_CLOSED_CHECK (using GET_PARACHUTE_VALVE)
- POS_OPEN_CHECK (using GET_PARACHUTE_VALVE)
- POS_CLOSED_CODE (using SET_PARACHUTE_VALVE)
- POS_OPEN_CODE (using SET_PARACHUTE_VALVE)
ParametersFn used:
- ASOBO_Auto_Define_XStates_Variant_Helper
- ASOBO_Watch_Simvar_Helper
Parameters set:
- SIMVAR (using PARACHUTE_VALVE_SIMVAR)
- ASOBO_Add_Set_Binding_Helper
Parameters set:
- ALIAS_ID
- PARAM_0
- PARAM_0_IS_DYNAMIC
- ASOBO_Add_Set_Binding_Helper
Parameters set:
- ALIAS_ID
- PARAM_0
- PARAM_0_IS_DYNAMIC
- Override
