On this page
Pneumatics_Interactions
Asobo_EX1\Common\Interior\Templates\ParametersFn\InteractionPresets\Pneumatics_Interactions.xml
ParametersFn
ASOBO_APU_Bleed_Settings_Config
Definition from XML<ParametersFn Name="ASOBO_APU_Bleed_Settings_Config"> <Parameters Type="Override"> <UseParametersFn Name="ASOBO_APU_Bleed_Parameters"/> </Parameters> <ReturnParameters> <UseParametersFn Name="ASOBO_Auto_Define_XStates_Variant_Helper"/> <UseParametersFn Name="ASOBO_Watch_Simvar_Helper"> <SIMVAR>#SIMVAR_APU_BLEED_AIR#</SIMVAR> </UseParametersFn> <POS_OFF_CHECK>#GET_APU_BLEED_AIR# !</POS_OFF_CHECK> <POS_ON_CHECK>#GET_APU_BLEED_AIR#</POS_ON_CHECK> <POS_OFF_CODE>0 #SET_APU_BLEED_AIR#</POS_OFF_CODE> <POS_ON_CODE>1 #SET_APU_BLEED_AIR#</POS_ON_CODE> </ReturnParameters> </ParametersFn>Parameters initialization:
- Override
ParametersFn used:
Return parameters:
Parameters set:
- POS_OFF_CHECK (using GET_APU_BLEED_AIR)
- POS_ON_CHECK (using GET_APU_BLEED_AIR)
- POS_OFF_CODE (using SET_APU_BLEED_AIR)
- POS_ON_CODE (using SET_APU_BLEED_AIR)
ParametersFn used:
- ASOBO_Auto_Define_XStates_Variant_Helper
- ASOBO_Watch_Simvar_Helper
Parameters set:
- SIMVAR (using SIMVAR_APU_BLEED_AIR)
- Override
ASOBO_Engine_Bleed_Settings_Config
Definition from XML<ParametersFn Name="ASOBO_Engine_Bleed_Settings_Config"> <Parameters Type="Default"> <ID>1</ID> </Parameters> <Parameters Type="Default"> <ENG_ID>#ID#</ENG_ID> </Parameters> <Parameters Type="Override"> <UseParametersFn Name="ASOBO_Engine_Bleed_Parameters"/> </Parameters> <ReturnParameters> <UseParametersFn Name="ASOBO_Auto_Define_XStates_Variant_Helper"/> <UseParametersFn Name="ASOBO_Watch_Simvar_Helper"> <SIMVAR>#SIMVAR_ENGINE_BLEED_AIR#</SIMVAR> </UseParametersFn> <POS_OFF_CHECK>#GET_ENGINE_BLEED_AIR# !</POS_OFF_CHECK> <POS_ON_CHECK>#GET_ENGINE_BLEED_AIR#</POS_ON_CHECK> <POS_OFF_CODE>0 #SET_ENGINE_BLEED_AIR#</POS_OFF_CODE> <POS_ON_CODE>1 #SET_ENGINE_BLEED_AIR#</POS_ON_CODE> </ReturnParameters> </ParametersFn>Parameters initialization:
- Default
Parameters set:
- ID
- Default
Parameters set:
- ENG_ID (using ID)
- Override
ParametersFn used:
Return parameters:
Parameters set:
- POS_OFF_CHECK (using GET_ENGINE_BLEED_AIR)
- POS_ON_CHECK (using GET_ENGINE_BLEED_AIR)
- POS_OFF_CODE (using SET_ENGINE_BLEED_AIR)
- POS_ON_CODE (using SET_ENGINE_BLEED_AIR)
ParametersFn used:
- ASOBO_Auto_Define_XStates_Variant_Helper
- ASOBO_Watch_Simvar_Helper
Parameters set:
- SIMVAR (using SIMVAR_ENGINE_BLEED_AIR)
- Default
ASOBO_Pneumatics_APU_Bleed_Settings_Config
Definition from XML<ParametersFn Name="ASOBO_Pneumatics_APU_Bleed_Settings_Config"> <Parameters Type="Override"> <UseParametersFn Name="ASOBO_Pneumatics_APU_Bleed_Parameters"/> </Parameters> <ReturnParameters> <UseParametersFn Name="ASOBO_Auto_Define_XStates_Variant_Helper"/> <UseParametersFn Name="ASOBO_Watch_Simvar_Helper"> <SIMVAR>#SIMVAR_APU_BLEED_AIR#</SIMVAR> </UseParametersFn> <POS_OFF_CHECK>#GET_APU_BLEED_AIR# !</POS_OFF_CHECK> <POS_ON_CHECK>#GET_APU_BLEED_AIR#</POS_ON_CHECK> <POS_OFF_CODE>0 #SET_APU_BLEED_AIR#</POS_OFF_CODE> <POS_ON_CODE>1 #SET_APU_BLEED_AIR#</POS_ON_CODE> </ReturnParameters> </ParametersFn>Parameters initialization:
- Override
ParametersFn used:
Return parameters:
Parameters set:
- POS_OFF_CHECK (using GET_APU_BLEED_AIR)
- POS_ON_CHECK (using GET_APU_BLEED_AIR)
- POS_OFF_CODE (using SET_APU_BLEED_AIR)
- POS_ON_CODE (using SET_APU_BLEED_AIR)
ParametersFn used:
- ASOBO_Auto_Define_XStates_Variant_Helper
- ASOBO_Watch_Simvar_Helper
Parameters set:
- SIMVAR (using SIMVAR_APU_BLEED_AIR)
- Override
ASOBO_Pneumatics_Engine_Bleed_Settings_Config
Definition from XML<ParametersFn Name="ASOBO_Pneumatics_Engine_Bleed_Settings_Config"> <Parameters Type="Default"> <ID>1</ID> </Parameters> <Parameters Type="Default"> <ENG_ID>#ID#</ENG_ID> </Parameters> <Parameters Type="Override"> <UseParametersFn Name="ASOBO_Pneumatics_Engine_Bleed_Parameters"/> </Parameters> <ReturnParameters> <UseParametersFn Name="ASOBO_Auto_Define_XStates_Variant_Helper"/> <UseParametersFn Name="ASOBO_Watch_Simvar_Helper"> <SIMVAR>#SIMVAR_ENGINE_BLEED_AIR#</SIMVAR> </UseParametersFn> <POS_OFF_CHECK>#GET_ENGINE_BLEED_AIR# !</POS_OFF_CHECK> <POS_ON_CHECK>#GET_ENGINE_BLEED_AIR#</POS_ON_CHECK> <POS_OFF_CODE>0 #SET_ENGINE_BLEED_AIR#</POS_OFF_CODE> <POS_ON_CODE>1 #SET_ENGINE_BLEED_AIR#</POS_ON_CODE> </ReturnParameters> </ParametersFn>Parameters initialization:
- Default
Parameters set:
- ID
- Default
Parameters set:
- ENG_ID (using ID)
- Override
ParametersFn used:
Return parameters:
Parameters set:
- POS_OFF_CHECK (using GET_ENGINE_BLEED_AIR)
- POS_ON_CHECK (using GET_ENGINE_BLEED_AIR)
- POS_OFF_CODE (using SET_ENGINE_BLEED_AIR)
- POS_ON_CODE (using SET_ENGINE_BLEED_AIR)
ParametersFn used:
- ASOBO_Auto_Define_XStates_Variant_Helper
- ASOBO_Watch_Simvar_Helper
Parameters set:
- SIMVAR (using SIMVAR_ENGINE_BLEED_AIR)
- Default
ASOBO_Pneumatics_Valve_Switch_Settings_Config
Definition from XML<ParametersFn Name="ASOBO_Pneumatics_Valve_Switch_Settings_Config"> <Parameters Type="Default"> <ID>1</ID> </Parameters> <Parameters Type="Default"> <VALVE_ID>#ID#</VALVE_ID> </Parameters> <Parameters Type="Override"> <UseParametersFn Name="ASOBO_Pneumatics_Valve_Parameters"/> </Parameters> <ReturnParameters> <UseParametersFn Name="ASOBO_Auto_Define_XStates_Variant_Helper"/> <UseParametersFn Name="ASOBO_Watch_Simvar_Helper"> <SIMVAR>#SIMVAR_VALVE_SWITCH#</SIMVAR> </UseParametersFn> <POS_CLOSED_CHECK>#GET_VALVE_SWITCH# !</POS_CLOSED_CHECK> <POS_OPEN_CHECK>#GET_VALVE_SWITCH#</POS_OPEN_CHECK> <POS_CLOSED_CODE>0 #SET_VALVE#</POS_CLOSED_CODE> <POS_OPEN_CODE>100 #SET_VALVE#</POS_OPEN_CODE> </ReturnParameters> </ParametersFn>Parameters initialization:
- Default
Parameters set:
- ID
- Default
Parameters set:
- VALVE_ID (using ID)
- Override
ParametersFn used:
Return parameters:
Parameters set:
- POS_CLOSED_CHECK (using GET_VALVE_SWITCH)
- POS_OPEN_CHECK (using GET_VALVE_SWITCH)
- POS_CLOSED_CODE (using SET_VALVE)
- POS_OPEN_CODE (using SET_VALVE)
ParametersFn used:
- ASOBO_Auto_Define_XStates_Variant_Helper
- ASOBO_Watch_Simvar_Helper
Parameters set:
- SIMVAR (using SIMVAR_VALVE_SWITCH)
- Default
ASOBO_Pneumatics_Valve_Mode_Settings_Config
Definition from XML<ParametersFn Name="ASOBO_Pneumatics_Valve_Mode_Settings_Config"> <Parameters Type="Default"> <ID>1</ID> </Parameters> <Parameters Type="Default"> <VALVE_ID>#ID#</VALVE_ID> </Parameters> <Parameters Type="Override"> <UseParametersFn Name="ASOBO_Pneumatics_Valve_Parameters"/> </Parameters> <ReturnParameters> <UseParametersFn Name="ASOBO_Auto_Define_XStates_Variant_Helper"/> <UseParametersFn Name="ASOBO_Watch_Simvar_Helper"> <SIMVAR>#SIMVAR_VALVE_MODE#</SIMVAR> </UseParametersFn> <POS_AUTO_CHECK>#GET_VALVE_MODE# 0 ==</POS_AUTO_CHECK> <POS_MANUAL_CHECK>#GET_VALVE_MODE# 1 ==</POS_MANUAL_CHECK> <POS_OPEN_CHECK>#GET_VALVE_MODE# 2 ==</POS_OPEN_CHECK> <POS_CLOSED_CHECK>#GET_VALVE_MODE# 3 ==</POS_CLOSED_CHECK> <POS_AUTO_CODE>0 #SET_VALVE_MODE#</POS_AUTO_CODE> <POS_MANUAL_CODE>1 #SET_VALVE_MODE#</POS_MANUAL_CODE> <POS_OPEN_CODE>2 #SET_VALVE_MODE#</POS_OPEN_CODE> <POS_CLOSED_CODE>3 #SET_VALVE_MODE#</POS_CLOSED_CODE> </ReturnParameters> </ParametersFn>Parameters initialization:
- Default
Parameters set:
- ID
- Default
Parameters set:
- VALVE_ID (using ID)
- Override
ParametersFn used:
Return parameters:
Parameters set:
- POS_AUTO_CHECK (using GET_VALVE_MODE)
- POS_MANUAL_CHECK (using GET_VALVE_MODE)
- POS_OPEN_CHECK (using GET_VALVE_MODE)
- POS_CLOSED_CHECK (using GET_VALVE_MODE)
- POS_AUTO_CODE (using SET_VALVE_MODE)
- POS_MANUAL_CODE (using SET_VALVE_MODE)
- POS_OPEN_CODE (using SET_VALVE_MODE)
- POS_CLOSED_CODE (using SET_VALVE_MODE)
ParametersFn used:
- ASOBO_Auto_Define_XStates_Variant_Helper
- ASOBO_Watch_Simvar_Helper
Parameters set:
- SIMVAR (using SIMVAR_VALVE_MODE)
- Default
ASOBO_Pneumatics_Valve_Settings_Config
Definition from XML<ParametersFn Name="ASOBO_Pneumatics_Valve_Settings_Config"> <Parameters Type="Default"> <ID>1</ID> <ENFORCE_MANUAL_MODE>True</ENFORCE_MANUAL_MODE> </Parameters> <Parameters Type="Default"> <VALVE_ID>#ID#</VALVE_ID> </Parameters> <Parameters Type="Override"> <UseParametersFn Name="ASOBO_Pneumatics_Valve_Parameters"/> </Parameters> <ReturnParameters> <Condition Valid="ENFORCE_MANUAL_MODE"> <UseParametersFn Name="ASOBO_Append_Init_Code_Helper"> <INIT_CODE>#IS_VALVE_MODE_MANUAL# ! if{ #SET_VALVE_MODE_MANUAL# }</INIT_CODE> </UseParametersFn> </Condition> <VALUE_TYPE>PERCENT</VALUE_TYPE> <IE_GET_STATE>#GET_VALVE_STATUS#</IE_GET_STATE> <IE_SET_STATE>#SET_VALVE# </IE_SET_STATE> <UseParametersFn Name="ASOBO_Watch_Simvar_Helper"> <SIMVAR>#SIMVAR_VALVE_STATUS#</SIMVAR> </UseParametersFn> </ReturnParameters> </ParametersFn>Parameters initialization:
- Default
Parameters set:
- ID
- ENFORCE_MANUAL_MODE
- Default
Parameters set:
- VALVE_ID (using ID)
- Override
ParametersFn used:
Return parameters:
Parameters set:
- VALUE_TYPE
- IE_GET_STATE (using GET_VALVE_STATUS)
- IE_SET_STATE (using SET_VALVE)
ParametersFn used:
- ASOBO_Watch_Simvar_Helper
Parameters set:
- SIMVAR (using SIMVAR_VALVE_STATUS)
Condition: Valid(ENFORCE_MANUAL_MODE)
- Case: True
ParametersFn used:
- ASOBO_Append_Init_Code_Helper
Parameters set:
- INIT_CODE (using IS_VALVE_MODE_MANUAL, SET_VALVE_MODE_MANUAL)
- ASOBO_Append_Init_Code_Helper
- Default
ASOBO_Pneumatics_Alternate_Static_Source_Settings_Config
Definition from XML<ParametersFn Name="ASOBO_Pneumatics_Alternate_Static_Source_Settings_Config"> <Parameters Type="Override"> <UseParametersFn Name="ASOBO_Pneumatics_Alternate_Static_Source_Parameters"/> </Parameters> <ReturnParameters> <UseParametersFn Name="ASOBO_Auto_Define_XStates_Variant_Helper"/> <UseParametersFn Name="ASOBO_Watch_Simvar_Helper"> <SIMVAR>#SIMVAR_ALTERNATE_STATIC_SOURCE_STATE#</SIMVAR> </UseParametersFn> <POS_CLOSED_CHECK>#GET_ALTERNATE_STATIC_SOURCE_STATE# !</POS_CLOSED_CHECK> <POS_OPEN_CHECK>#GET_ALTERNATE_STATIC_SOURCE_STATE#</POS_OPEN_CHECK> <POS_CLOSED_CODE>#SET_ALTERNATE_STATIC_SOURCE_CLOSED#</POS_CLOSED_CODE> <POS_OPEN_CODE>#SET_ALTERNATE_STATIC_SOURCE_OPEN#</POS_OPEN_CODE> </ReturnParameters> </ParametersFn>Parameters initialization:
- Override
ParametersFn used:
Return parameters:
Parameters set:
- POS_CLOSED_CHECK (using GET_ALTERNATE_STATIC_SOURCE_STATE)
- POS_OPEN_CHECK (using GET_ALTERNATE_STATIC_SOURCE_STATE)
- POS_CLOSED_CODE (using SET_ALTERNATE_STATIC_SOURCE_CLOSED)
- POS_OPEN_CODE (using SET_ALTERNATE_STATIC_SOURCE_OPEN)
ParametersFn used:
- ASOBO_Auto_Define_XStates_Variant_Helper
- ASOBO_Watch_Simvar_Helper
Parameters set:
- SIMVAR (using SIMVAR_ALTERNATE_STATIC_SOURCE_STATE)
- Override
ASOBO_PNEUMATICS_AREA_TEMPERATURE_SELECT_Settings_Config
Definition from XML<ParametersFn Name="ASOBO_PNEUMATICS_AREA_TEMPERATURE_SELECT_Settings_Config"> <Parameters Type="Default"> <AREA_ID>1</AREA_ID> </Parameters> <Condition NotEmpty="AREA_NAME"> <Parameters Type="Override"> <AREA_ID>'#AREA_NAME#'_n</AREA_ID> </Parameters> </Condition> <Parameters Type="Override"> <UseParametersFn Name="ASOBO_Pneumatics_Area_Parameters"/> </Parameters> <ReturnParameters> <UseParametersFn Name="ASOBO_Watch_Simvar_Helper"> <SIMVAR>#SIMVAR_AREA_TARGET_TEMPERATURE_PCT#</SIMVAR> </UseParametersFn> <VALUE_TYPE>PERCENT</VALUE_TYPE> <IE_GET_STATE>#GET_AREA_TARGET_TEMPERATURE_PCT#</IE_GET_STATE> <IE_SET_STATE>#SET_AREA_TARGET_TEMPERATURE_PCT#</IE_SET_STATE> </ReturnParameters> </ParametersFn>Parameters initialization:
- Default
Parameters set:
- AREA_ID
- Override
ParametersFn used:
Return parameters:
Parameters set:
- VALUE_TYPE
- IE_GET_STATE (using GET_AREA_TARGET_TEMPERATURE_PCT)
- IE_SET_STATE (using SET_AREA_TARGET_TEMPERATURE_PCT)
ParametersFn used:
- ASOBO_Watch_Simvar_Helper
Parameters set:
- SIMVAR (using SIMVAR_AREA_TARGET_TEMPERATURE_PCT)
- Default
ASOBO_PNEUMATICS_PACK_SWITCH_Settings_Config
Definition from XML<ParametersFn Name="ASOBO_PNEUMATICS_PACK_SWITCH_Settings_Config"> <Parameters Type="Default"> <PACK_ID>1</PACK_ID> </Parameters> <Parameters Type="Default"> <UseParametersFn Name="ASOBO_Pneumatics_Pack_Parameters"/> </Parameters> <ReturnParameters> <UseParametersFn Name="ASOBO_Auto_Define_XStates_Variant_Helper"/> <UseParametersFn Name="ASOBO_Watch_Simvar_Helper"> <SIMVAR>#SIMVAR_PACK_SWITCH#</SIMVAR> </UseParametersFn> <POS_ON_CHECK>#GET_PACK_SWITCH#</POS_ON_CHECK> <POS_OFF_CHECK>#GET_PACK_SWITCH# !</POS_OFF_CHECK> <POS_ON_CODE>#SET_PACK_ON#</POS_ON_CODE> <POS_OFF_CODE>#SET_PACK_OFF#</POS_OFF_CODE> </ReturnParameters> </ParametersFn>Parameters initialization:
- Default
Parameters set:
- PACK_ID
- Default
ParametersFn used:
Return parameters:
Parameters set:
- POS_ON_CHECK (using GET_PACK_SWITCH)
- POS_OFF_CHECK (using GET_PACK_SWITCH)
- POS_ON_CODE (using SET_PACK_ON)
- POS_OFF_CODE (using SET_PACK_OFF)
ParametersFn used:
- ASOBO_Auto_Define_XStates_Variant_Helper
- ASOBO_Watch_Simvar_Helper
Parameters set:
- SIMVAR (using SIMVAR_PACK_SWITCH)
- Default