[Go back to index]
Asobo\Misc\ASDigitalFuelMeter_FP5L.xml
Source XML
<ModelBehaviors>
<Include RelativeFile="Inputs\\Misc_Inputs.xml"/>
<Template Name="ASOBO_ASDigitalFuelMeter_FP5L_Template">
<Parameters Type="Default">
<ID>1</ID>
</Parameters>
<UseTemplate Name="ASOBO_GT_Helper_Suffix_ID_Appender">
<TEMPLATE_TO_CALL>ASOBO_ASDigitalFuelMeter_FP5L_SubTemplate</TEMPLATE_TO_CALL>
</UseTemplate>
</Template>
<Template Name="ASOBO_ASDigitalFuelMeter_FP5L_SubTemplate">
<Parameters Type="Default">
<NODE_ID_SCREEN>INSTRUMENT_FUEL_SCREEN#SUFFIX_ID#</NODE_ID_SCREEN>
<NODE_ID_SWITCH>BUTTON_DIGITALFUELMETER_STEP#SUFFIX_ID#</NODE_ID_SWITCH>
<ANIM_NAME_SWITCH>BUTTON_DIGITALFUELMETER_STEP#SUFFIX_ID#</ANIM_NAME_SWITCH>
<NODE_ID_LEFT_BUTTON>BUTTON_DIGITALFUELMETER_DES#SUFFIX_ID#</NODE_ID_LEFT_BUTTON>
<ANIM_NAME_LEFT_BUTTON>BUTTON_DIGITALFUELMETER_DES#SUFFIX_ID#</ANIM_NAME_LEFT_BUTTON>
<NODE_ID_RIGHT_BUTTON>BUTTON_DIGITALFUELMETER_RES#SUFFIX_ID#</NODE_ID_RIGHT_BUTTON>
<ANIM_NAME_RIGHT_BUTTON>BUTTON_DIGITALFUELMETER_RES#SUFFIX_ID#</ANIM_NAME_RIGHT_BUTTON>
<NODE_ID_LED_1>LIGHT_DIGITALFUELMETER_FLOW_HP#SUFFIX_ID#</NODE_ID_LED_1>
<NODE_ID_LED_2>LIGHT_DIGITALFUELMETER_REM#SUFFIX_ID#</NODE_ID_LED_2>
<NODE_ID_LED_3>LIGHT_DIGITALFUELMETER_FUEL_USED#SUFFIX_ID#</NODE_ID_LED_3>
<NODE_ID_LED_4>LIGHT_DIGITALFUELMETER_MPG#SUFFIX_ID#</NODE_ID_LED_4>
<NODE_ID_LED_5>LIGHT_DIGITALFUELMETER_AUX#SUFFIX_ID#</NODE_ID_LED_5>
<NODE_ID_WARNING_LED_LOWFUEL>LIGHT_DIGITALFUELMETER_LOWFUEL#SUFFIX_ID#</NODE_ID_WARNING_LED_LOWFUEL>
<NODE_ID_WARNING_LED_HL_AUX>LIGHT_DIGITALFUELMETER_HL_AUX#SUFFIX_ID#</NODE_ID_WARNING_LED_HL_AUX>
<!-- Switch Mode -->
<POS_LEFT>0</POS_LEFT>
<POS_MED>1</POS_MED>
<POS_RIGHT>2</POS_RIGHT>
<WWISE_PREFIX>asDigitalFuelMeterFP5L</WWISE_PREFIX>
<MOMENTARY_TIMER_SWITCH>0.1</MOMENTARY_TIMER_SWITCH>
</Parameters>
<Component ID="DigitalFuelMeter_FP5L">
<Component ID="#NODE_ID_SCREEN#" Node="#NODE_ID_SCREEN#">
<UseTemplate Name="ASOBO_GT_Emissive_Gauge">
<EMISSIVE_CODE>0.5</EMISSIVE_CODE>
</UseTemplate>
</Component>
<UseTemplate Name="ASOBO_AS_DigitalFuelMeter_FP5L_Base_Template">
<IE_NAME>Switch</IE_NAME>
<INTERACTION_TYPE>Switch</INTERACTION_TYPE>
<NUM_STATES>3</NUM_STATES>
<MOMENTARY_SWITCH>True</MOMENTARY_SWITCH>
<STATE_MAX_TIMER>#MOMENTARY_TIMER_SWITCH#</STATE_MAX_TIMER>
<STATE0_TIMER>#MOMENTARY_TIMER_SWITCH#</STATE0_TIMER>
<SWITCH_DIRECTION>Horizontal</SWITCH_DIRECTION>
<SET_STATE_#POS_LEFT#>(>H:DigitalFuelMeter_FP5L_SwitchLeft)</SET_STATE_#POS_LEFT#>
<SET_STATE_#POS_MED#></SET_STATE_#POS_MED#>
<SET_STATE_#POS_RIGHT#>(>H:DigitalFuelMeter_FP5L_SwitchRight)</SET_STATE_#POS_RIGHT#>
<GET_STATE_EXTERNAL>1</GET_STATE_EXTERNAL>
<ENUM_VAL_TO_POS_EXTERNAL>l0</ENUM_VAL_TO_POS_EXTERNAL>
<STR_STATE_#POS_LEFT#>Left</STR_STATE_#POS_LEFT#>
<STR_STATE_#POS_MED#>Center</STR_STATE_#POS_MED#>
<STR_STATE_#POS_RIGHT#>Right</STR_STATE_#POS_RIGHT#>
<TT_VALUE_#POS_LEFT#>@TT_Package.GT_STATE_LEFT</TT_VALUE_#POS_LEFT#>
<TT_VALUE_#POS_MED#>@TT_Package.GT_STATE_MED</TT_VALUE_#POS_MED#>
<TT_VALUE_#POS_RIGHT#>@TT_Package.GT_STATE_RIGHT</TT_VALUE_#POS_RIGHT#>
<NODE_ID>#NODE_ID_SWITCH#</NODE_ID>
<ANIM_NAME>#ANIM_NAME_SWITCH#</ANIM_NAME>
<TOOLTIP_TITLE>@TT_Package.DIGITALFUELMETER_FP5L_SWITCH_TITLE</TOOLTIP_TITLE>
<TT_DESCRIPTION_ID>@TT_Package.DIGITALFUELMETER_FP5L_SWITCH_ACTION</TT_DESCRIPTION_ID>
</UseTemplate>
<UseTemplate Name="ASOBO_AS_DigitalFuelMeter_FP5L_Base_Template">
<IE_NAME>LeftButton</IE_NAME>
<INTERACTION_TYPE>Push</INTERACTION_TYPE>
<SET_STATE_EXTERNAL>if{ (>H:DigitalFuelMeter_FP5L_LeftButtonPush) }</SET_STATE_EXTERNAL>
<NODE_ID>#NODE_ID_LEFT_BUTTON#</NODE_ID>
<ANIM_NAME>#ANIM_NAME_LEFT_BUTTON#</ANIM_NAME>
<TOOLTIP_TITLE>@TT_Package.DIGITALFUELMETER_FP5L_LEFT_BUTTON_TITLE</TOOLTIP_TITLE>
<TT_DESCRIPTION_ID>@TT_Package.DIGITALFUELMETER_FP5L_LEFT_BUTTON_ACTION</TT_DESCRIPTION_ID>
</UseTemplate>
<UseTemplate Name="ASOBO_AS_DigitalFuelMeter_FP5L_Base_Template">
<IE_NAME>RightButton</IE_NAME>
<INTERACTION_TYPE>Push</INTERACTION_TYPE>
<SET_STATE_EXTERNAL>if{ (>H:DigitalFuelMeter_FP5L_RightButtonPush) }</SET_STATE_EXTERNAL>
<NODE_ID>#NODE_ID_RIGHT_BUTTON#</NODE_ID>
<ANIM_NAME>#ANIM_NAME_RIGHT_BUTTON#</ANIM_NAME>
<TOOLTIP_TITLE>@TT_Package.DIGITALFUELMETER_FP5L_RIGHT_BUTTON_TITLE</TOOLTIP_TITLE>
<TT_DESCRIPTION_ID>@TT_Package.DIGITALFUELMETER_FP5L_RIGHT_BUTTON_ACTION</TT_DESCRIPTION_ID>
</UseTemplate>
<Component ID="DigitalFuelMeter_FP5L_Switch_Leds">
<Loop>
<Setup>
<Param>LED_ID</Param>
<From>1</From>
<Inc>1</Inc>
<To>5</To>
</Setup>
<Do>
<UseTemplate Name="ASOBO_GT_Component_Emissive_Gauge">
<NODE_ID Process="Param">NODE_ID_LED_#LED_ID#</NODE_ID>
<EMISSIVE_CODE>(L:DigitalFuelMeter_FP5L_PAGE_LED) #LED_ID# ==</EMISSIVE_CODE>
</UseTemplate>
</Do>
</Loop>
</Component>
<Component ID="DigitalFuelMeter_FP5L_Warning_Leds">
<UseTemplate Name="DigitalFuelMeter_FP5L_Warning_Led">
<NODE_ID>#NODE_ID_WARNING_LED_LOWFUEL#</NODE_ID>
<LVAR>DigitalFuelMeter_FP5L_LOW_FUEL_LIGHT</LVAR>
</UseTemplate>
<UseTemplate Name="DigitalFuelMeter_FP5L_Warning_Led">
<NODE_ID>#NODE_ID_WARNING_LED_HL_AUX#</NODE_ID>
<LVAR>DigitalFuelMeter_FP5L_HL_AUX_LIGHT</LVAR>
</UseTemplate>
</Component>
</Component>
</Template>
<Template Name="DigitalFuelMeter_FP5L_Warning_Led">
<UseTemplate Name="ASOBO_GT_Component_Emissive_Gauge">
<EMISSIVE_CODE>1</EMISSIVE_CODE>
<BLINK>True</BLINK>
<BLINK_DURATION>(L:#LVAR#) 50 *</BLINK_DURATION>
</UseTemplate>
</Template>
<Template Name="ASOBO_AS_DigitalFuelMeter_FP5L_Base_Template">
<Parameters Type="Default">
<INPUT_EVENT_ID_SOURCE>AS_DigitalFuelMeter_FP5L</INPUT_EVENT_ID_SOURCE>
</Parameters>
<UseTemplate Name="ASOBO_Interaction_Base_Template">
<USE_INPUT_EVENT_ID>AS_DigitalFuelMeter_FP5L</USE_INPUT_EVENT_ID>
</UseTemplate>
</Template>
</ModelBehaviors>
Includes
- RelativeFile: Inputs\\Misc_Inputs.xml
Templates
Template list
-
ASOBO_ASDigitalFuelMeter_FP5L_Template
Definition from XML<Template Name="ASOBO_ASDigitalFuelMeter_FP5L_Template"> <Parameters Type="Default"> <ID>1</ID> </Parameters> <UseTemplate Name="ASOBO_GT_Helper_Suffix_ID_Appender"> <TEMPLATE_TO_CALL>ASOBO_ASDigitalFuelMeter_FP5L_SubTemplate</TEMPLATE_TO_CALL> </UseTemplate> </Template>Parameters initialization:
-
Default
Parameters set:
- ID
Templates used:
-
ASOBO_GT_Helper_Suffix_ID_Appender
- May include a subtemplate using the parameter 'TEMPLATE_TO_CALL' and resolve to the following template(s):
Parameters set:
- TEMPLATE_TO_CALL
-
Default
-
ASOBO_ASDigitalFuelMeter_FP5L_SubTemplate
Definition from XML<Template Name="ASOBO_ASDigitalFuelMeter_FP5L_SubTemplate"> <Parameters Type="Default"> <NODE_ID_SCREEN>INSTRUMENT_FUEL_SCREEN#SUFFIX_ID#</NODE_ID_SCREEN> <NODE_ID_SWITCH>BUTTON_DIGITALFUELMETER_STEP#SUFFIX_ID#</NODE_ID_SWITCH> <ANIM_NAME_SWITCH>BUTTON_DIGITALFUELMETER_STEP#SUFFIX_ID#</ANIM_NAME_SWITCH> <NODE_ID_LEFT_BUTTON>BUTTON_DIGITALFUELMETER_DES#SUFFIX_ID#</NODE_ID_LEFT_BUTTON> <ANIM_NAME_LEFT_BUTTON>BUTTON_DIGITALFUELMETER_DES#SUFFIX_ID#</ANIM_NAME_LEFT_BUTTON> <NODE_ID_RIGHT_BUTTON>BUTTON_DIGITALFUELMETER_RES#SUFFIX_ID#</NODE_ID_RIGHT_BUTTON> <ANIM_NAME_RIGHT_BUTTON>BUTTON_DIGITALFUELMETER_RES#SUFFIX_ID#</ANIM_NAME_RIGHT_BUTTON> <NODE_ID_LED_1>LIGHT_DIGITALFUELMETER_FLOW_HP#SUFFIX_ID#</NODE_ID_LED_1> <NODE_ID_LED_2>LIGHT_DIGITALFUELMETER_REM#SUFFIX_ID#</NODE_ID_LED_2> <NODE_ID_LED_3>LIGHT_DIGITALFUELMETER_FUEL_USED#SUFFIX_ID#</NODE_ID_LED_3> <NODE_ID_LED_4>LIGHT_DIGITALFUELMETER_MPG#SUFFIX_ID#</NODE_ID_LED_4> <NODE_ID_LED_5>LIGHT_DIGITALFUELMETER_AUX#SUFFIX_ID#</NODE_ID_LED_5> <NODE_ID_WARNING_LED_LOWFUEL>LIGHT_DIGITALFUELMETER_LOWFUEL#SUFFIX_ID#</NODE_ID_WARNING_LED_LOWFUEL> <NODE_ID_WARNING_LED_HL_AUX>LIGHT_DIGITALFUELMETER_HL_AUX#SUFFIX_ID#</NODE_ID_WARNING_LED_HL_AUX> <POS_LEFT>0</POS_LEFT> <POS_MED>1</POS_MED> <POS_RIGHT>2</POS_RIGHT> <WWISE_PREFIX>asDigitalFuelMeterFP5L</WWISE_PREFIX> <MOMENTARY_TIMER_SWITCH>0.1</MOMENTARY_TIMER_SWITCH> </Parameters> <Component ID="DigitalFuelMeter_FP5L"> <Component ID="#NODE_ID_SCREEN#" Node="#NODE_ID_SCREEN#"> <UseTemplate Name="ASOBO_GT_Emissive_Gauge"> <EMISSIVE_CODE>0.5</EMISSIVE_CODE> </UseTemplate> </Component> <UseTemplate Name="ASOBO_AS_DigitalFuelMeter_FP5L_Base_Template"> <IE_NAME>Switch</IE_NAME> <INTERACTION_TYPE>Switch</INTERACTION_TYPE> <NUM_STATES>3</NUM_STATES> <MOMENTARY_SWITCH>True</MOMENTARY_SWITCH> <STATE_MAX_TIMER>#MOMENTARY_TIMER_SWITCH#</STATE_MAX_TIMER> <STATE0_TIMER>#MOMENTARY_TIMER_SWITCH#</STATE0_TIMER> <SWITCH_DIRECTION>Horizontal</SWITCH_DIRECTION> <SET_STATE_#POS_LEFT#>(>H:DigitalFuelMeter_FP5L_SwitchLeft)</SET_STATE_#POS_LEFT#> <SET_STATE_#POS_MED#/> <SET_STATE_#POS_RIGHT#>(>H:DigitalFuelMeter_FP5L_SwitchRight)</SET_STATE_#POS_RIGHT#> <GET_STATE_EXTERNAL>1</GET_STATE_EXTERNAL> <ENUM_VAL_TO_POS_EXTERNAL>l0</ENUM_VAL_TO_POS_EXTERNAL> <STR_STATE_#POS_LEFT#>Left</STR_STATE_#POS_LEFT#> <STR_STATE_#POS_MED#>Center</STR_STATE_#POS_MED#> <STR_STATE_#POS_RIGHT#>Right</STR_STATE_#POS_RIGHT#> <TT_VALUE_#POS_LEFT#>@TT_Package.GT_STATE_LEFT</TT_VALUE_#POS_LEFT#> <TT_VALUE_#POS_MED#>@TT_Package.GT_STATE_MED</TT_VALUE_#POS_MED#> <TT_VALUE_#POS_RIGHT#>@TT_Package.GT_STATE_RIGHT</TT_VALUE_#POS_RIGHT#> <NODE_ID>#NODE_ID_SWITCH#</NODE_ID> <ANIM_NAME>#ANIM_NAME_SWITCH#</ANIM_NAME> <TOOLTIP_TITLE>@TT_Package.DIGITALFUELMETER_FP5L_SWITCH_TITLE</TOOLTIP_TITLE> <TT_DESCRIPTION_ID>@TT_Package.DIGITALFUELMETER_FP5L_SWITCH_ACTION</TT_DESCRIPTION_ID> </UseTemplate> <UseTemplate Name="ASOBO_AS_DigitalFuelMeter_FP5L_Base_Template"> <IE_NAME>LeftButton</IE_NAME> <INTERACTION_TYPE>Push</INTERACTION_TYPE> <SET_STATE_EXTERNAL>if{ (>H:DigitalFuelMeter_FP5L_LeftButtonPush) }</SET_STATE_EXTERNAL> <NODE_ID>#NODE_ID_LEFT_BUTTON#</NODE_ID> <ANIM_NAME>#ANIM_NAME_LEFT_BUTTON#</ANIM_NAME> <TOOLTIP_TITLE>@TT_Package.DIGITALFUELMETER_FP5L_LEFT_BUTTON_TITLE</TOOLTIP_TITLE> <TT_DESCRIPTION_ID>@TT_Package.DIGITALFUELMETER_FP5L_LEFT_BUTTON_ACTION</TT_DESCRIPTION_ID> </UseTemplate> <UseTemplate Name="ASOBO_AS_DigitalFuelMeter_FP5L_Base_Template"> <IE_NAME>RightButton</IE_NAME> <INTERACTION_TYPE>Push</INTERACTION_TYPE> <SET_STATE_EXTERNAL>if{ (>H:DigitalFuelMeter_FP5L_RightButtonPush) }</SET_STATE_EXTERNAL> <NODE_ID>#NODE_ID_RIGHT_BUTTON#</NODE_ID> <ANIM_NAME>#ANIM_NAME_RIGHT_BUTTON#</ANIM_NAME> <TOOLTIP_TITLE>@TT_Package.DIGITALFUELMETER_FP5L_RIGHT_BUTTON_TITLE</TOOLTIP_TITLE> <TT_DESCRIPTION_ID>@TT_Package.DIGITALFUELMETER_FP5L_RIGHT_BUTTON_ACTION</TT_DESCRIPTION_ID> </UseTemplate> <Component ID="DigitalFuelMeter_FP5L_Switch_Leds"> <Loop> <Setup> <Param>LED_ID</Param> <From>1</From> <Inc>1</Inc> <To>5</To> </Setup> <Do> <UseTemplate Name="ASOBO_GT_Component_Emissive_Gauge"> <NODE_ID Process="Param">NODE_ID_LED_#LED_ID#</NODE_ID> <EMISSIVE_CODE>(L:DigitalFuelMeter_FP5L_PAGE_LED) #LED_ID# ==</EMISSIVE_CODE> </UseTemplate> </Do> </Loop> </Component> <Component ID="DigitalFuelMeter_FP5L_Warning_Leds"> <UseTemplate Name="DigitalFuelMeter_FP5L_Warning_Led"> <NODE_ID>#NODE_ID_WARNING_LED_LOWFUEL#</NODE_ID> <LVAR>DigitalFuelMeter_FP5L_LOW_FUEL_LIGHT</LVAR> </UseTemplate> <UseTemplate Name="DigitalFuelMeter_FP5L_Warning_Led"> <NODE_ID>#NODE_ID_WARNING_LED_HL_AUX#</NODE_ID> <LVAR>DigitalFuelMeter_FP5L_HL_AUX_LIGHT</LVAR> </UseTemplate> </Component> </Component> </Template>Parameters initialization:
-
Default
Parameters set:
- NODE_ID_SCREEN (using SUFFIX_ID)
- NODE_ID_SWITCH (using SUFFIX_ID)
- ANIM_NAME_SWITCH (using SUFFIX_ID)
- NODE_ID_LEFT_BUTTON (using SUFFIX_ID)
- ANIM_NAME_LEFT_BUTTON (using SUFFIX_ID)
- NODE_ID_RIGHT_BUTTON (using SUFFIX_ID)
- ANIM_NAME_RIGHT_BUTTON (using SUFFIX_ID)
- NODE_ID_LED_1 (using SUFFIX_ID)
- NODE_ID_LED_2 (using SUFFIX_ID)
- NODE_ID_LED_3 (using SUFFIX_ID)
- NODE_ID_LED_4 (using SUFFIX_ID)
- NODE_ID_LED_5 (using SUFFIX_ID)
- NODE_ID_WARNING_LED_LOWFUEL (using SUFFIX_ID)
- NODE_ID_WARNING_LED_HL_AUX (using SUFFIX_ID)
- POS_LEFT
- POS_MED
- POS_RIGHT
- WWISE_PREFIX
- MOMENTARY_TIMER_SWITCH
Components:
-
DigitalFuelMeter_FP5L
Parameters read:
- NODE_ID_SCREEN
Components:
-
#NODE_ID_SCREEN# (Node: #NODE_ID_SCREEN#)
Templates used:
-
ASOBO_GT_Emissive_Gauge
Parameters set:
- EMISSIVE_CODE
-
ASOBO_GT_Emissive_Gauge
-
DigitalFuelMeter_FP5L_Switch_Leds
Parameters set:
- LED_ID
Templates used:
-
ASOBO_GT_Component_Emissive_Gauge
Parameters set:
- NODE_ID (using LED_ID)
- EMISSIVE_CODE (using LED_ID)
-
DigitalFuelMeter_FP5L_Warning_Leds
Templates used:
-
DigitalFuelMeter_FP5L_Warning_Led
Parameters set:
- NODE_ID (using NODE_ID_WARNING_LED_LOWFUEL)
- LVAR
-
DigitalFuelMeter_FP5L_Warning_Led
Parameters set:
- NODE_ID (using NODE_ID_WARNING_LED_HL_AUX)
- LVAR
-
DigitalFuelMeter_FP5L_Warning_Led
Templates used:
-
ASOBO_AS_DigitalFuelMeter_FP5L_Base_Template
Parameters set:
- IE_NAME
- INTERACTION_TYPE
- NUM_STATES
- MOMENTARY_SWITCH
- STATE_MAX_TIMER (using MOMENTARY_TIMER_SWITCH)
- STATE0_TIMER (using MOMENTARY_TIMER_SWITCH)
- SWITCH_DIRECTION
- SET_STATE_#POS_LEFT#
- SET_STATE_#POS_MED#
- SET_STATE_#POS_RIGHT#
- GET_STATE_EXTERNAL
- ENUM_VAL_TO_POS_EXTERNAL
- STR_STATE_#POS_LEFT#
- STR_STATE_#POS_MED#
- STR_STATE_#POS_RIGHT#
- TT_VALUE_#POS_LEFT#
- TT_VALUE_#POS_MED#
- TT_VALUE_#POS_RIGHT#
- NODE_ID (using NODE_ID_SWITCH)
- ANIM_NAME (using ANIM_NAME_SWITCH)
- TOOLTIP_TITLE
- TT_DESCRIPTION_ID
-
ASOBO_AS_DigitalFuelMeter_FP5L_Base_Template
Parameters set:
- IE_NAME
- INTERACTION_TYPE
- SET_STATE_EXTERNAL
- NODE_ID (using NODE_ID_LEFT_BUTTON)
- ANIM_NAME (using ANIM_NAME_LEFT_BUTTON)
- TOOLTIP_TITLE
- TT_DESCRIPTION_ID
-
ASOBO_AS_DigitalFuelMeter_FP5L_Base_Template
Parameters set:
- IE_NAME
- INTERACTION_TYPE
- SET_STATE_EXTERNAL
- NODE_ID (using NODE_ID_RIGHT_BUTTON)
- ANIM_NAME (using ANIM_NAME_RIGHT_BUTTON)
- TOOLTIP_TITLE
- TT_DESCRIPTION_ID
-
Default
-
DigitalFuelMeter_FP5L_Warning_Led
Definition from XML<Template Name="DigitalFuelMeter_FP5L_Warning_Led"> <UseTemplate Name="ASOBO_GT_Component_Emissive_Gauge"> <EMISSIVE_CODE>1</EMISSIVE_CODE> <BLINK>True</BLINK> <BLINK_DURATION>(L:#LVAR#) 50 *</BLINK_DURATION> </UseTemplate> </Template>Templates used:
-
ASOBO_GT_Component_Emissive_Gauge
Parameters set:
- EMISSIVE_CODE
- BLINK
- BLINK_DURATION (using LVAR)
-
ASOBO_GT_Component_Emissive_Gauge
-
ASOBO_AS_DigitalFuelMeter_FP5L_Base_Template
Definition from XML<Template Name="ASOBO_AS_DigitalFuelMeter_FP5L_Base_Template"> <Parameters Type="Default"> <INPUT_EVENT_ID_SOURCE>AS_DigitalFuelMeter_FP5L</INPUT_EVENT_ID_SOURCE> </Parameters> <UseTemplate Name="ASOBO_Interaction_Base_Template"> <USE_INPUT_EVENT_ID>AS_DigitalFuelMeter_FP5L</USE_INPUT_EVENT_ID> </UseTemplate> </Template>Parameters initialization:
-
Default
Parameters set:
- INPUT_EVENT_ID_SOURCE
Templates used:
-
ASOBO_Interaction_Base_Template
Parameters set:
- USE_INPUT_EVENT_ID
-
Default